Potentiometric pCO2 sensor using polyaniline-coated pH-sensitive electrodes

被引:53
作者
Cui, G
Lee, JS
Kim, SJ
Nam, H
Cha, GS
Kim, HD
机构
[1] Kwangwoon Univ, Dept Chem, Nowon Ku, Seoul 139701, South Korea
[2] Kyunghee Univ, Dept Chem, Seoul 130701, South Korea
关键词
D O I
10.1039/a802872i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A very simple method of constructing a differential pCO(2) sensor device is described, using polyaniline-based pH electrodes in place of the pH-ISFET-based system employed previously. The polyaniline:film-coated Pt electrode. was shown to exhibit not only an enhanced potentiometric pH response but also a greatly reduced oxygen sensitivity compared with the uncoated Pt electrode. The proposed differential system employs two identical polyaniline electrodes to make a pCO(2) probe and a reference electrode. Both electrodes are made by coating the polyaniline surface with a gas-permeable silicone rubber membrane doped with valinomycin. The pCO(2) electrode is covered with a hydrogel-based recipient layer inside the gas-permeable membrane whereas the reference electrode does not have the hydrogel layer. In this sensor configuration, the emf differences between the pCO(2) and the reference electrodes serve as analytical signals and hence the ion responses caused by the two parts of the outer gas-permeable membranes cancel out. The polyaniline-based gas sensor system was shown to provide better emf stability than the uncoated Pt electrode-based counterpart.
引用
收藏
页码:1855 / 1859
页数:5
相关论文
共 29 条
[21]   MINIATURE INTRAVASCULAR PCO2 SENSORS IN NEUROSURGERY [J].
NEUMARK, J ;
BARDEEN, A ;
SULZER, E ;
KAMPINE, JP .
JOURNAL OF NEUROSURGERY, 1975, 43 (02) :172-176
[22]   INVIVO MEASUREMENT OF CARBON-DIOXIDE TENSION WITH A MINIATURE ELECTRODE [J].
OLIEVIER, CN ;
BERKENBOSCH, A ;
QUANJER, PH .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1978, 373 (03) :269-272
[23]  
OPDYCKE WN, 1986, ANAL CHEM, V58, P950, DOI 10.1021/ac00295a062
[24]   ELECTRODES FOR BLOOD PO2 AND PCO2 DETERMINATION [J].
SEVERINGHAUS, JW ;
BRADLEY, AF .
JOURNAL OF APPLIED PHYSIOLOGY, 1958, 13 (03) :515-520
[25]   ISFET-based differential pCO(2) sensors employing a low-resistance gas-permeable membrane [J].
Shin, JH ;
Lee, HJ ;
Kim, CY ;
Oh, BK ;
Rho, KL ;
Nam, H ;
Cha, GS .
ANALYTICAL CHEMISTRY, 1996, 68 (18) :3166-3172
[26]   MICRO FLOW CELL FOR BLOOD-GAS ANALYSIS REALIZING VERY SMALL SAMPLE VOLUME [J].
SHOJI, S ;
ESASHI, M .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 8 (02) :205-208
[27]   AN INTEGRATED CHEMICAL SENSOR WITH MULTIPLE ION AND GAS SENSORS [J].
TSUKADA, K ;
MIYAHARA, Y ;
SHIBATA, Y ;
MIYAGI, H .
SENSORS AND ACTUATORS B-CHEMICAL, 1990, 2 (04) :291-295
[28]   SINGLE-UNIT CARBON DIOXIDE OXYGEN SENSING MICROELECTRODE SYSTEM [J].
VANKEMPEN, LHJ ;
KREUZER, F .
RESPIRATION PHYSIOLOGY, 1975, 23 (03) :371-379
[29]   Determination of pH using a polyaniline-coated piezoelectric crystal [J].
Zhou, XY ;
Cha, HY ;
Yang, C ;
Zhang, WM .
ANALYTICA CHIMICA ACTA, 1996, 329 (1-2) :105-109