Temporal dynamics of the BOLD fMRI impulse response

被引:85
作者
de Zwart, JA
Silva, AC
van Gelderen, P
Kellman, P
Fukunaga, M
Chu, RX
Koretsky, AP
Frank, JA
Duyn, JH
机构
[1] NINDS, Adv MRI Sect, LFMI, NIH, Bethesda, MD 20892 USA
[2] NHLBI, Cardiac Energet Lab, NIH, Bethesda, MD 20892 USA
[3] NIH, Lab Diagnost Radiol Res, CC, Bethesda, MD 20892 USA
关键词
BOLD fMRI; binary m-sequence; hemodynamic response; vascular dispersion;
D O I
10.1016/j.neuroimage.2004.09.013
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Using computer simulations and high-resolution fMRI experiments in humans (n = 6) and rats (n = 8) we investigated to what extent BOLD fMRI temporal resolution is limited by dispersion in the venous vasculature. For this purpose, time-to-peak (TTP) and full-width at half-maximum (FWHM) of the BOLD impulse response (IR) function were determined. In fMRI experiments, a binary in-sequence probe method was used to obtain high-sensitivity model-free single-pixel estimates of IR. Simulations of posteapillary flow suggested that flow-related dispersion leads to a TTP and FWHM increase, which can amount to several seconds in larger pial veins. fMRI experiments showed substantial spatial variation in IR timing within human visual cortex, together with a correlation between TTP and FWHM. Averaged across the activated regions and across subjects, TTP and FWHM were 4.51 +/- 0.52 and 4.04 +/- 0.42 s, respectively. In regions of interest (ROI) weighted toward the larger venous structures, TTP and FWHM increased to 5.07 +/- 0.64 and 4.32 +/- 0.48 s, respectively. In rat somatosensory cortex, TTP and FWHM were substantially shorter than in humans (2.73 +/- 0.60 and 2.28 +/- 0.63 s, respectively). These results are consistent with a substantial macrovascular dispersive contribution to BOLD IR in humans, and furthermore suggest that neurovascular coupling is a relatively rapid process, with a resolution below 2.3 s FWHM. Published by Elsevier Inc.
引用
收藏
页码:667 / 677
页数:11
相关论文
共 63 条
[21]   Retinotopic organization in human visual cortex and the spatial precision of functional MRI [J].
Engel, SA ;
Glover, GH ;
Wandell, BA .
CEREBRAL CORTEX, 1997, 7 (02) :181-192
[22]  
Friston K., 1994, HUM BRAIN MAPP, V1, P153, DOI [10.1002/hbm.460010207, DOI 10.1002/HBM.460010207]
[23]   CORTICAL FUNCTIONAL ARCHITECTURE AND LOCAL COUPLING BETWEEN NEURONAL-ACTIVITY AND THE MICROCIRCULATION REVEALED BY INVIVO HIGH-RESOLUTION OPTICAL IMAGING OF INTRINSIC SIGNALS [J].
FROSTIG, RD ;
LIEKE, EE ;
TSO, DY ;
GRINVALD, A .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1990, 87 (16) :6082-6086
[24]  
Hoge RD, 1999, MAGNET RESON MED, V42, P849, DOI 10.1002/(SICI)1522-2594(199911)42:5<849::AID-MRM4>3.0.CO
[25]  
2-Z
[26]  
HUDETZ AG, 1992, ADV EXP MED BIOL, V317, P659
[27]   VIDEO MICROSCOPY OF CEREBROCORTICAL CAPILLARY-FLOW - RESPONSE TO HYPOTENSION AND INTRACRANIAL HYPERTENSION [J].
HUDETZ, AG ;
FEHER, G ;
WEIGLE, CGM ;
KNUESE, DE ;
KAMPINE, JP .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1995, 268 (06) :H2202-H2210
[28]   Local and propagated vascular responses evoked by focal synaptic activity in cerebellar cortex [J].
Iadecola, C ;
Yang, G ;
Ebner, TJ ;
Chen, G .
JOURNAL OF NEUROPHYSIOLOGY, 1997, 78 (02) :651-659
[29]   Method for functional MRI mapping of nonlinear response [J].
Kellman, P ;
van Gelderen, P ;
de Zwart, JA ;
Duyn, JH .
NEUROIMAGE, 2003, 19 (01) :190-199
[30]   High-resolution mapping of iso-orientation columns by fMRI [J].
Kim, DS ;
Duong, TQ ;
Kim, SG .
NATURE NEUROSCIENCE, 2000, 3 (02) :164-169