Conventional, confocal and two-photon fluorescence microscopy investigations of polymer-supported oxygen sensors

被引:17
作者
Bowman, RD
Kneas, KA [1 ]
Demas, JN
Periasamy, A
机构
[1] Maryville Coll, Div Nat Sci, Maryville, TN 37804 USA
[2] Univ Virginia, Dept Chem, Charlottesville, VA 22904 USA
[3] Univ Virginia, WM Keck Ctr Cellular Imaging, Charlottesville, VA 22904 USA
来源
JOURNAL OF MICROSCOPY-OXFORD | 2003年 / 211卷
关键词
confocal; conventional microscopy; fluorescence; luminescence; oxygen sensors; polymer; quenching; ruthenium; Stern-Volmer; two-photon microscopy; OPTICAL MICROSCOPY; METAL-COMPLEXES; FILMS; RUTHENIUM(II); EXCITATION;
D O I
10.1046/j.1365-2818.2003.01192.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
Luminescence-based, polymer-supported oxygen sensors, particularly those based on platinum group complexes, continue to be of analytical importance. Commercial applications range from the macroscopic (e.g. aerodynamic investigations in wind tunnels, monitoring of oxygen concentration during fermentation, and measurement of biological oxygen demand) to the microscopic (e.g. imaging of oxygen in blood, tissue, cells and other biological samples). Problems hindering the design of improved oxygen sensors include non-linear Stern-Volmer calibration plots and the multi-exponentiality of measured lifetime decays, both of which are attributed primarily to heterogeneity of the sensor molecule in the polymer support matrix. Conventional, confocal and two-photon fluorescence microscopy have proven to be invaluable tools with which the microscale heterogeneity and response of luminescence-based oxygen sensors can be investigated and compared to the macroscopic response. Results obtained for three ruthenium(II) alpha-diimine complexes in polydimethylsiloxane polymer supports indicate the presence of unquenched microcrystals within the polymer matrix that probably degrade oxygen quenching sensitivity and linearity of the Stern-Volmer quenching plot. Two-photon fluorescence microscopy proved most useful for imaging microcrystals within sensor films, and conventional microscopy allowed direct comparison between microscopic and macroscopic sensor response. The implications of the results in the rational design and mass production of luminescence-based oxygen sensors are significant.
引用
收藏
页码:112 / 120
页数:9
相关论文
共 20 条
[1]   Two-dimensional polymers investigated by scanning near-field optical microscopy: Phase separation of polymer blend monolayer [J].
Aoki, H ;
Ito, S .
JOURNAL OF PHYSICAL CHEMISTRY B, 2001, 105 (20) :4558-4564
[2]   Micro-heterogeneous oxygen response in luminescence sensor films [J].
Bedlek-Anslow, JM ;
Hubner, JP ;
Carroll, BF ;
Schanze, KS .
LANGMUIR, 2000, 16 (24) :9137-9141
[3]   LUMINESCENCE QUENCHING MECHANISM FOR MICROHETEROGENEOUS SYSTEMS [J].
CARRAWAY, ER ;
DEMAS, JN ;
DEGRAFF, BA .
ANALYTICAL CHEMISTRY, 1991, 63 (04) :332-336
[4]  
Demas J.N., 1991, ANAL CHEM, V63, P829
[5]   Oxygen sensors based on luminescence quenching [J].
Demas, JN ;
DeGraff, BA ;
Coleman, PB .
ANALYTICAL CHEMISTRY, 1999, 71 (23) :793A-800A
[6]   MODELING OF LUMINESCENCE QUENCHING-BASED SENSORS - COMPARISON OF MULTISITE AND NONLINEAR GAS SOLUBILITY MODELS [J].
DEMAS, JN ;
DEGRAFF, BA ;
XU, WY .
ANALYTICAL CHEMISTRY, 1995, 67 (08) :1377-1380
[7]   INTERSYSTEM CROSSING YIELDS IN RUTHENIUM(II) AND OSMIUM(II) PHOTOSENSITIZERS [J].
DEMAS, JN ;
TAYLOR, DG .
INORGANIC CHEMISTRY, 1979, 18 (11) :3177-3179
[8]  
Kneas KA, 2000, MICROSC MICROANAL, V6, P551, DOI 10.1007/s100050010052
[9]   Oxygen sensors based on luminescence quenching: Interactions of tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(II) chloride and pyrene with polymer supports [J].
Kneas, KA ;
Xu, WY ;
Demas, JN ;
DeGraff, BA .
APPLIED SPECTROSCOPY, 1997, 51 (09) :1346-1351
[10]   Comparison of conventional, confocal, and two-photon microscopy for detection of microcrystals within luminescence-based oxygen sensor films [J].
Kneas, KA ;
Demas, JN ;
DeGraff, BA ;
Periasamy, A .
MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES, 2001, 4262 :89-97