On-line microfluidic sensor integrated with a micro array electrode and enzyme-modified pre-reactor for the real-time monitoring of blood catecholamine

被引:41
作者
Hayashi, K
Iwasaki, Y
Kurita, R
Sunagawa, K
Niwa, O
机构
[1] NTT Corp, Microsyst Integrat Labs, Atsugi, Kanagawa 2430198, Japan
[2] NTT Corp, Adv Technol Corp, Atsugi, Kanagawa 2430198, Japan
[3] Natl Cardiovasc Ctr, Suita, Osaka 5658565, Japan
关键词
microfluidic device; interdigitated array electrode; micro pre-reactor; catecholamine; ascorbic acid; real-time monitoring;
D O I
10.1016/j.elecom.2003.10.005
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
We developed an on-line microfluidic sensing device with an interdigitated array (IDA) electrode and a micro pre-reactor for the real-time monitoring of blood catecholamine (CA) and succeeded in the highly sensitive detection of dopamine (DA) in the presence of L-ascorbic acid (AA). Our device exhibits the lowest detection limit (110 +/- 10 pM (S/N = 3)), of reported catecholamine sensors. The improvement in sensitivity results from the high redox cycling of DA and the increase in the mass transfer rate per unit time onto the IDA electrode achieved by the flow measurement. The pre-reactor was integrated upstream in the micro flow channel to eliminate AA. A large number of rectangular shaped micropillars, which were modified with ascorbate oxidase, were formed in the pre-reactor to increase the surface area. The flow was disturbed by the two dimensional micropillar arrangement. This structure enables us to increase the elimination efficiency for AA. As a result, we achieved both the continuous and highly selective detection of 1 nM DA with complete elimination of 10 muM AA in the sample solution without employing any selective membrane such as Nafion, whose use reduces sensitivity due to the low diffusion coefficient of DA inside the membrane. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:1037 / 1042
页数:6
相关论文
共 15 条
[1]  
COHN JN, N ENGL J MED, V311, P819
[2]  
Collins A, 2001, ELECTROANAL, V13, P425, DOI 10.1002/1521-4109(200104)13:6<425::AID-ELAN425>3.0.CO
[3]  
2-5
[4]   Selective detection Of L-glutamate using a microfluldic device integrated with an enzyme-modified pre-reactor and an electrochemical detector [J].
Hayashi, K ;
Kurita, R ;
Horiuchi, T ;
Niwa, O .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (10) :1249-1255
[5]   Hydrodynamic properties of the electrochemical behavior using interdigitated array microelectrodes [J].
Hoshino, S ;
Niwa, O ;
Tabei, H ;
Takahashi, M ;
Morita, M .
DENKI KAGAKU, 1996, 64 (03) :195-201
[6]  
Issopoulos PB, 1996, FARMACO, V51, P673
[7]  
JURGEN W, 2002, CLIN LAB HEIDELBERG, V48, P61
[8]   IMPROVED DETECTION LIMIT FOR CATECHOLAMINES USING LIQUID-CHROMATOGRAPHY ELECTROCHEMISTRY WITH A CARBON INTERDIGITATED ARRAY MICROELECTRODE [J].
NIWA, O ;
TABEI, H ;
SOLOMON, BP ;
XIE, FM ;
KISSINGER, PT .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1995, 670 (01) :21-28
[9]   Aromatic glycinonitriles and methylamines as pre-column fluorescence derivatization reagents for catecholamines [J].
Nohta, H ;
Yukizawa, T ;
Ohkura, Y ;
Yoshimura, M ;
Ishida, J ;
Yamaguchi, M .
ANALYTICA CHIMICA ACTA, 1997, 344 (03) :233-240
[10]   Chemiluminescence determination of catecholamines in human blood plasma using 1,2-bis(3-chlorophenyl)ethylenediamine as pre-column derivatizing reagent for liquid chromatography [J].
Ragab, GH ;
Nohta, H ;
Zaitsu, K .
ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) :155-160