Validation for tremor quantification of an electromagnetic tracking device

被引:44
作者
O'Suilleabhain, PE [1 ]
Dewey, RB [1 ]
机构
[1] Univ Texas, SW Med Ctr, Dept Neurol, Dallas, TX 75390 USA
关键词
essential tremor; Parkinson's disease; tremor quantification; electromagnetic tracking device;
D O I
10.1002/mds.1064
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
An electromagnetic tracking system was used to record arm motion in subjects with Parkinson's disease(n = 23), essential tremor(n = 28) or without neurological disease (n = 4). Tremor magnitude was calculated by averaging the three-dimensional displacement of individual tremor bursts. Tremor magnitude calculated in this manner was quite closely correlated with a clinician's estimate (r = 0.88 and 0.86 for Parkinsonian and essential tremors, respectively) and was reproducible (r = 0.93 for repeated recordings). The accuracy of the device and algorithm was confirmed by mechanically generating oscillations of known magnitudes and frequencies. This device is adaptable for quantifying different types of tremors and its accuracy is easy to verify. Because position rather than acceleration is tracked, tremor amplitude can be stated in readily comprehensible units. (C) 2001 Movement Disorder Society.
引用
收藏
页码:265 / 271
页数:7
相关论文
共 16 条
[1]   ASSESSING TREMOR SEVERITY [J].
BAIN, PG ;
FINDLEY, LJ ;
ATCHISON, P ;
BEHARI, M ;
VIDAILHET, M ;
GRESTY, M ;
ROTHWELL, JC ;
THOMPSON, PD ;
MARSDEN, CD .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1993, 56 (08) :868-873
[2]   Assessment of combined movements of the lumbar spine in asymptomatic and low back pain subjects using a three-dimensional electromagnetic tracking system [J].
Barrett, CJ ;
Singer, KP ;
Day, R .
MANUAL THERAPY, 1999, 4 (02) :94-99
[3]   THE MEASUREMENT OF TREMOR USING SIMPLE LASER SYSTEMS [J].
BEUTER, A ;
DEGEOFFROY, A ;
CORDO, P .
JOURNAL OF NEUROSCIENCE METHODS, 1994, 53 (01) :47-54
[4]   QUANTIFICATION OF TREMOR WITH A DIGITIZING TABLET [J].
ELBLE, RJ ;
SINHA, R ;
HIGGINS, C .
JOURNAL OF NEUROSCIENCE METHODS, 1990, 32 (03) :193-198
[5]   Quantification of essential tremor in writing and drawing [J].
Elble, RJ ;
Brilliant, M ;
Leffler, K ;
Higgins, C .
MOVEMENT DISORDERS, 1996, 11 (01) :70-78
[6]  
Fahn S., 1988, PARKINSONS DIS MOVEM, P225
[7]   Feasibility of using a magnetic tracking device for measuring carpal kinematics [J].
Ishikawa, J ;
Niebur, GL ;
Uchiyama, S ;
Linscheid, RL ;
Minami, A ;
Kaneda, K ;
An, KN .
JOURNAL OF BIOMECHANICS, 1997, 30 (11-12) :1183-1186
[8]   QUANTITATIVE ASSESSMENT OF PARKINSONIAN AND ESSENTIAL TREMOR - CLINICAL-APPLICATION OF TRIAXIAL ACCELEROMETRY [J].
JANKOVIC, J ;
FROST, JD .
NEUROLOGY, 1981, 31 (10) :1235-1240
[9]   Validity of a performance-based test of function in essential tremor [J].
Louis, ED ;
Wendt, KJ ;
Albert, SM ;
Pullman, SL ;
Yu, QP ;
Andrews, H .
ARCHIVES OF NEUROLOGY, 1999, 56 (07) :841-846
[10]  
Louis ED, 2000, MOVEMENT DISORD, V15, P95, DOI 10.1002/1531-8257(200001)15:1<95::AID-MDS1015>3.0.CO