Determination of endocrine disruptors in environmental water samples by stir bar sorptive extraction-liquid desorption -: Large volume injection-gas chromatography

被引:32
作者
Brossa, L [1 ]
Marcé, RM [1 ]
Borrull, F [1 ]
Pocurull, E [1 ]
机构
[1] Univ Rovira & Virgili, Dept Quim Anal & Quim Organ, Tarragona 43005, Spain
关键词
gas chromatography-mass spectrometry; large volume injection; stir bar sorptive extraction; endocrine disruptors; environmental water samples;
D O I
10.1365/s10337-004-0447-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method based on stir bar sorptive extraction with liquid desorption combined with gas chromatography and mass spectrometry detection has been developed to determine a group of endocrine disruptors in water samples. Large volume injection was used with a programmed temperature vaporiser injector in gas chromatography to enhance sensitivity. The parameters affecting stir bar sorptive extraction and large volume injection were optimised. The limits of quantification in the full scan mode were between 0.02 and 0.2 mug L-1 and the limits of detection were between 0.005 and 0.02 mug L-1 for river water samples. The reproducibility between days of the method (n = 3) for river water samples spiked at 0.2 mug L-1 was below 15%. The performance of the method was checked with several water samples from the sea, and effluent and influent sewage treatment plants. We found 4-tert-octylphenol, benzylbutyl phthalate and bis(2-ethylhexyl) adipate in all the water samples analysed at levels between 0.02-14.04 mug L-1. Diazinon was found in only one effluent wastewater sample at 0.16 mug L-1.
引用
收藏
页码:61 / 65
页数:5
相关论文
共 28 条
[1]   Trace determination of priority pesticides in water by means of high-speed on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry using turbulent-flow chromatography columns for enrichment and a short monolithic column for fast liquid chromatographic separation [J].
Asperger, A ;
Efer, J ;
Koal, T ;
Engewald, W .
JOURNAL OF CHROMATOGRAPHY A, 2002, 960 (1-2) :109-119
[2]  
Baltussen E, 1999, J MICROCOLUMN SEP, V11, P737, DOI 10.1002/(SICI)1520-667X(1999)11:10<737::AID-MCS7>3.0.CO
[3]  
2-4
[4]   Determination of endocrine-disrupting compounds in water samples by on-line solid-phase extraction-programmed-temperature vaporisation-gas chromatography-mass spectrometry [J].
Brossa, L ;
Marcé, RM ;
Borrull, F ;
Pocurull, E .
JOURNAL OF CHROMATOGRAPHY A, 2003, 998 (1-2) :41-50
[5]  
COLBRON T, 2004, WIDESPREAD POLLUTANT
[6]  
*COMM COMM COUNC E, 2001, APPL COMM STRAT ENDR
[7]   Liquid chromatography-(tandem) mass spectrometry of selected emerging pollutants (steroid sex hormones, drugs and alkylphenolic surfactants) in the aquatic environment [J].
de Alda, MJL ;
Díaz-Cruz, S ;
Petrovic, M ;
Barceló, D .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :503-526
[8]   Simultaneous determination of estrogenic short ethoxy chain nonylphenols and their acidic metabolites in water by an in-sample derivatization/solid-phase microextraction method [J].
Díaz, A ;
Ventura, F ;
Galceran, MT .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :3869-3876
[9]   Monitoring of endocrine disruptors in surface waters by the yeast recombinant assay [J].
García-Reyero, N ;
Grau, E ;
Castillo, M ;
De Alda, MJL ;
Barceló, D ;
Piña, B .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2001, 20 (06) :1152-1158
[10]   Development of the ELISAs for detection of hormone-disrupting chemicals [J].
Goda, Y ;
Kobayashi, A ;
Fukuda, K ;
Fujimoto, S ;
Ike, M ;
Fujita, M .
WATER SCIENCE AND TECHNOLOGY, 2000, 42 (7-8) :81-88