Effect of reconstruction algorithm on image quality and identification of ground-glass opacities and partly solid nodules on low-dose thin-section CT: Experimental study using chest phantom

被引:12
作者
Koyama, Hisanobu [1 ]
Ohno, Yoshiharu [2 ]
Kono, Atsushi A. [2 ]
Kusaka, Akiko [2 ]
Konishi, Minoru [2 ]
Yoshii, Masaru [2 ]
Sugimura, Kazuro [2 ]
机构
[1] Hyogo Kaibara Hosp, Dept Radiol, Kaibara, Tanba 6693395, Japan
[2] Kobe Univ, Dept Radiol, Grad Sch Med, Chuo Ku, Kobe, Hyogo 6500017, Japan
关键词
Lung; High-resolution CT; Radiation dose; Reconstruction algorithm; MAXIMUM-INTENSITY-PROJECTION; PULMONARY NODULES; LUNG-CANCER; COMPUTED-TOMOGRAPHY; FLEISCHNER-SOCIETY; MULTIDETECTOR CT; ROW CT; STATEMENT;
D O I
10.1016/j.ejrad.2009.03.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: The purpose of this study was to assess the influence of reconstruction algorithm on identification and image quality of ground-glass opacities (GGOs) and partly solid nodules on low-dose thin-section CT. Materials and methods: A chest CT phantom including simulated GGOs and partly solid nodules was scanned with five different tube currents and reconstructed by using standard(A) and newly developed (B) high-resolution reconstruction algorithms, followed by visually assessment of identification and image quality of GGOs and partly solid nodules by two chest radiologists. Inter-observer agreement, ROC analysis and ANOVA were performed to compare identification and image quality of each data set with those of the standard reference. The standard reference used 120 mA s in conjunction with reconstruction algorithm A. Results: Kappa values (kappa) of overall identification and image qualities were substantial or almost perfect (0.60 < kappa). Assessment of identification showed that area under the curve of 25 mA reconstructed with reconstruction algorithm A was significantly lower than that of standard reference (p < 0.05), while assessment of image quality indicated that 50 mA s reconstructed with reconstruction algorithm A and 25 mA s reconstructed with both reconstruction algorithms were significantly lower than standard reference (p < 0.05). Conclusion: Reconstruction algorithm may be an important factor for identification and image quality of ground-glass opacities and partly solid nodules on low-dose CT examination. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:500 / 507
页数:8
相关论文
共 20 条
[1]
Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness [J].
Fischbach, F ;
Knollmann, F ;
Griesshaber, V ;
Freund, T ;
Akkol, E ;
Felix, R .
EUROPEAN RADIOLOGY, 2003, 13 (10) :2378-2383
[2]
Incremental benefit of maximum-intensity-projection images on observer detection of small pulmonary nodules revealed by multidetector CT [J].
Gruden, JF ;
Ouanounou, S ;
Tigges, S ;
Norris, SD ;
Klausner, TS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (01) :149-157
[3]
Early Lung Cancer Action Project: A summary of the findings on baseline screening [J].
Henschke, CI ;
McCauley, DI ;
Yankelevitz, DF ;
Naidich, DP ;
McGuinness, G ;
Miettinen, OS ;
Libby, D ;
Pasmantier, M ;
Koizumi, J ;
Altorki, N ;
Smith, JP .
ONCOLOGIST, 2001, 6 (02) :147-152
[4]
Henschke CI, 2006, NEW ENGL J MED, V355, P1763, DOI 10.1056/NEJMoa060476
[5]
Computer-assisted lung nodule volumetry from multi-detector row CT: Influence of image reconstruction parameters [J].
Honda, Osamu ;
Sumikawa, Hiromitsu ;
Johkoh, Takeshi ;
Tomiyama, Noriyuki ;
Mihara, Naoki ;
Inoue, Atsuo ;
Tsubamoto, Mitsuko ;
Natsag, Javzandulam ;
Hamada, Seiki ;
Nakamura, Hironobu .
EUROPEAN JOURNAL OF RADIOLOGY, 2007, 62 (01) :106-113
[6]
Pulmonary nodule detection using chest CT images [J].
Kim, DY ;
Kim, JH ;
Noh, SM ;
Park, JW .
ACTA RADIOLOGICA, 2003, 44 (03) :252-257
[7]
Ground-glass opacity on thin-section CT: Value in differentiating subtypes of adenocarcinoma of the lung [J].
Kuriyama, K ;
Seto, M ;
Kasugai, T ;
Higashiyama, M ;
Kido, S ;
Sawai, Y ;
Kodama, K ;
Kuroda, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (02) :465-469
[8]
Identification and characterization of focal ground-glass opacity in the lungs by high-resolution CT using thin-section multidetector helical CT: experimental study using a chest CT phantom [J].
Liu, Duo ;
Awai, Kazuo ;
Funama, Yoshinori ;
Oda, Seitaro ;
Nakaura, Takeshi ;
Yanaga, Yumi ;
Hatemura, Masahiro ;
Kawanaka, Koichi ;
Yamashita, Yasuyuki .
RADIATION MEDICINE, 2008, 26 (01) :21-27
[9]
Guidelines for management of small pulmonary nodules detected on CT scans: A statement from the Fleischner Society [J].
MacMahon, H ;
Austin, JHM ;
Gamsu, G ;
Herold, CJ ;
Jett, JR ;
Naidich, DP ;
Patz, EF ;
Swensen, SJ .
RADIOLOGY, 2005, 237 (02) :395-400
[10]
Radiation exposure at chest CT:: A statement of the Fleischner Society [J].
Mayo, JR ;
Aldrich, J ;
Müller, NL .
RADIOLOGY, 2003, 228 (01) :15-21