Radiation exposure at chest CT:: A statement of the Fleischner Society

被引:255
作者
Mayo, JR [1 ]
Aldrich, J [1 ]
Müller, NL [1 ]
机构
[1] Vancouver Gen Hosp, Dept Radiol, Vancouver, BC V5Z 1M9, Canada
关键词
computed tomography (CT); radiation exposure; radiations; exposure to patients and personnel; measurement; thorax; CT;
D O I
10.1148/radiol.2281020874
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The introduction of helical single-detector row computed tomography (CT) and, more recently, multi-detector row CT has greatly increased the clinical indications for CT. Correspondingly, CT examinations now account for greater than one-half of the radiation dose due to medical procedures in the population of North America. The level of CT radiation dose, especially in the pediatric population, is of concern to radiologists, medical physicists, government regulators, and the media. This review addresses this problem with particular reference to radiation dose in chest CT. Specifically it outlines the topics of measurement units used to quantify radiation exposure, factors affecting CT scanner dose efficiency, scanner settings that determine the administered radiation dose, and radiation dose reduction in chest CT. A table of reference dose values is provided. Given the wide variation documented in chest CT radiation exposure, the authors suggest that reference standards be promoted to minimize excessive CT radiation exposure. In addition, further research into the complex relationship between radiation exposure, image quality, and diagnostic accuracy should be encouraged in order to establish the minimum radiation dose necessary to provide adequate diagnostic information for standard clinical questions. (C) RSNA, 2003.
引用
收藏
页码:15 / 21
页数:7
相关论文
共 85 条
  • [1] [Anonymous], 1995, MED EFFECTS IONIZING
  • [2] Energy imparted and effective doses in computed tomography
    Atherton, JV
    Huda, W
    [J]. MEDICAL PHYSICS, 1996, 23 (05) : 735 - 741
  • [3] Beir V., 1990, HLTH EFFECTS EXPOSUR, DOI DOI 10.17226/1224
  • [4] Multidetector-array CT: Once again, technology creates new opportunities
    Berland, LL
    Smith, JK
    [J]. RADIOLOGY, 1998, 209 (02) : 327 - 329
  • [5] Estimating cancer risks from pediatric CT: going from the qualitative to the quantitative
    Brenner, DJ
    [J]. PEDIATRIC RADIOLOGY, 2002, 32 (04) : 228 - 231
  • [6] Estimated risks of radiation-induced fatal cancer from pediatric CT
    Brenner, DJ
    Elliston, CD
    Hall, EJ
    Berdon, WE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) : 289 - 296
  • [7] CT scanner design and patient radiation exposure
    Brody, AS
    [J]. PEDIATRIC RADIOLOGY, 2002, 32 (04) : 268 - 271
  • [8] Effective dose in paediatric computed tomography
    Chapple, CL
    Willis, S
    Frame, J
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (01) : 107 - 115
  • [9] AVERAGE RADIATION-DOSE IN STANDARD CT EXAMINATIONS OF THE HEAD - RESULTS OF THE 1990 NEXT SURVEY
    CONWAY, BJ
    MCCROHAN, JL
    ANTONSEN, RG
    RUETER, FG
    SLAYTON, RJ
    SULEIMAN, OH
    [J]. RADIOLOGY, 1992, 184 (01) : 135 - 140
  • [10] CUNNINGHAM IA, 1995, BIOMEDICAL ENG HDB, P990