A fully automated synthesis for the preparation of 68Ga-labelled peptides

被引:109
作者
Decristoforo, Clemens
Knopp, Roger
von Guggenberg, Elisabeth
Rupprich, Marco
Dreger, Thorsten
Hess, Andre
Virgolini, Irene
Haubner, Roland
机构
[1] Med Univ Innsbruck, Clin Dept Nucl Med, Innsbruck, Austria
[2] Eckert & Ziegler Eurotope GmbH, Berlin, Germany
关键词
Ga-68; DOTATOC; automated synthesis; peptides; PET;
D O I
10.1097/MNM.0b013e3282f1753d
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Background Generator-produced Ga-68 has attracted increasing interest for radiolabelling peptides used in PET applications. So far, the synthesis of Ga-68-peptide radiopharmaceuticals is mainly based on semi-automated systems. Here we describe a fully automated approach for the synthesis of Ga-68-labelled peptides. Method A commercially available Ga-68 generator was eluted with 0.1 mol . I-1 HCI. Reaction parameters such as buffer conditions, pH range, reaction temperature and time, volume of reaction solution and generator fraction were optimized for labelling DOTA-Tyr(3)-octreotide (DOTATOC). Reaction yields, pH, radiochemical purity, sterility, endotoxins, breakthrough of (68)e and final Ge-68 content were determined. A fully automated radiopharmaceutical synthesis device based on a modular concept for remote-ontrolled processing was developed and evaluated for a number of DOTA-derivatized peptides. Results DOTATOC could be labelled in almost quantitative yields by heating 10-50 nmol peptide at PH 3.5-4.0 for 5 min at 95 degrees C in 1.5 ml. Purification using a reversed-phase cartridge was required to avoid any potential 1 68Ge breakthrough: final activities of Ge-68 were below 100 Bq . ml(-1). Automated synthesis resulted in overall decay-corrected reaction yields of about 60% within 10 min. Even after 1 year using a 1110 MBq generator more than 130 MBq Ga-68-DOTATOC could be obtained. Moreover, it was demonstrated that a variety of DOTA-derivatized peptides can be labelled using identical reaction conditions with high yields. Conclusion The system described allows the fully automated, efficient and rapid preparation of Ga-68-DOTA-derivatized pepticles. It has been used successfully and reliably for routine preparations in clinical studies.
引用
收藏
页码:870 / 875
页数:6
相关论文
共 12 条
[1]
Infrared-based module for the synthesis of 68Ga-labeled radiotracers [J].
Azhdarinia, Ali ;
Yang, David J. ;
Chao, Clifford ;
Mourtada, Firas .
NUCLEAR MEDICINE AND BIOLOGY, 2007, 34 (01) :121-127
[2]
Radiolabelling DOTA-peptides with 68Ga [J].
Breeman, WAP ;
de Jong, M ;
de Blois, E ;
Bernard, BF ;
Konijnenberg, M ;
Krenning, EP .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 (04) :478-485
[3]
The 68Ge/68Ga generator has high potential, but when can we use 68Ga-labelled tracers in clinical routine? [J].
Breeman, Wouter A. P. ;
Verbruggen, Alfons M. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (07) :978-981
[4]
DEUTSCH E, 1993, J NUCL MED, V34, P1132
[5]
68Ga-DOTA-Tyr3-octreotide PET in neuroendocrine tumors:: Comparison with somatostatin receptor scintigraphy and CT [J].
Gabriel, Michael ;
Decristoforo, Clemens ;
Kendler, Dorota ;
Dobrozemsky, Georg ;
Heute, Dirk ;
Uprimny, Christian ;
Kovacs, Peter ;
Von Guggenberg, Elisabeth ;
Bale, Reto ;
Virgolini, Irene J. .
JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (04) :508-518
[6]
HAYES RL, 1965, J NUCL MED, V6, P605
[7]
Biokinetics and imaging with the somatostatin receptor PET radioligand 68Ga-DOTATOC:: preliminary data [J].
Hofmann, M ;
Maecke, H ;
Börner, AR ;
Weckesser, E ;
Schöffski, P ;
Oei, ML ;
Schumacher, J ;
Henze, M ;
Heppeler, A ;
Meyer, GJ ;
Knapp, WH .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (12) :1751-1757
[8]
Maecke HR, 2005, J NUCL MED, V46, p172S
[9]
68Ga-labelled DOTA-derivatised peptide ligands [J].
Meyer, GJ ;
Mäcke, H ;
Schuhmacher, J ;
Knapp, WH ;
Hofmann, M .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (08) :1097-1104
[10]
ROSCH F, 2006, NUKLEARMEDIZIN, V44, pA191