American Association of Physicists in Medicine radiation therapy committee task group 53: Quality assurance for clinical radiotherapy treatment planning

被引:646
作者
Fraass, B
Doppke, K
Hunt, M
Kutcher, G
Starkschall, G
Stern, R
Van Dyke, J
机构
[1] Univ Michigan, Med Ctr, Ann Arbor, MI 48109 USA
[2] Massachusetts Gen Hosp, Boston, MA 02114 USA
[3] Fox Chase Canc Ctr, Philadelphia, PA 19111 USA
[4] Mem Sloan Kettering Canc Ctr, New York, NY 10021 USA
[5] MD Anderson Canc Ctr, Houston, TX USA
[6] Univ Calif Davis, Med Ctr, Sacramento, CA 95817 USA
[7] London Reg Canc Ctr, London, ON N6A 4L6, Canada
关键词
treatment planning; quality assurance; 3D treatment planning;
D O I
10.1118/1.598373
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In recent years, the sophistication and complexity of clinical treatment planning and treatment planning systems has increased significantly, particularly including three-dimensional (3D) treatment planning systems, and the use of conformal treatment planning and delivery techniques. This has led to the need for a comprehensive set of quality assurance (QA) guidelines that can be applied to clinical treatment planning. This document is the report of Task Group 53 of the Radiation Therapy Committee of the American Association of Physicists in Medicine. The purpose of this report is to guide and assist the clinical medical physicist in developing and implementing a comprehensive but viable program of quality assurance for modern radiotherapy treatment planning. The scope of the QA needs for treatment planning is quite broad, encompassing image-based definition of patient anatomy, 3D beam descriptions for complex beams including multileaf collimator apertures, 3D dose calculation algorithms, and complex plan evaluation tools including dose volume histograms. The Task Group recommends an organizational framework for the task of creating a QA program which is individualized to the needs of each institution and addresses the issues of acceptance testing, commissioning the planning system and planning process, routine quality assurance, and ongoing QA of the planning process. This report, while not prescribing specific QA tests, provides the framework and guidance to allow radiation oncology physicists to design comprehensive and practical treatment planning QA programs for their clinics. (C) 1998 American Association of Physicists in Medicine. [S0094-2405(98)03410-5].
引用
收藏
页码:1773 / 1829
页数:57
相关论文
共 80 条
[1]   COLLAPSED CONE CONVOLUTION OF RADIANT ENERGY FOR PHOTON DOSE CALCULATION IN HETEROGENEOUS MEDIA [J].
AHNESJO, A .
MEDICAL PHYSICS, 1989, 16 (04) :577-592
[2]  
ANDERSON L, 1990, INTERSTITIAL BRACHYT, P360
[3]  
[Anonymous], 1978, 29 ICRU
[4]  
[Anonymous], 1993, 50 ICRU
[5]  
*APPM, 1995, 55 APPM
[6]   CORRELATION OF PROJECTION RADIOGRAPHS IN RADIATION-THERAPY USING OPEN CURVE SEGMENTS AND POINTS [J].
BALTER, JM ;
PELIZZARI, CA ;
CHEN, GTY .
MEDICAL PHYSICS, 1992, 19 (02) :329-334
[7]  
BAXTER BS, 1982, 10 AAPM
[8]  
Boyer AL, 1996, TELETHERAPY PRESENT, P403
[9]   AUTOMATIC-GENERATION OF BEAM APERTURES [J].
BREWSTER, L ;
MAGERAS, GS ;
MOHAN, R .
MEDICAL PHYSICS, 1993, 20 (05) :1337-1342
[10]  
BURMAN C, 1989, MED PHYS, V16, P465