Multisignaling optical-electrochemical sensor for Hg2+ based on a rhodamine derivative with a ferrocene unit

被引:330
作者
Yang, Hong
Zhou, Zhiguo
Huang, Kewei
Yu, Mengxiao
Li, Fuyou
Yi, Tao
Huang, Chunhui [1 ]
机构
[1] Fudan Univ, Dept Chem, Shanghai 200433, Peoples R China
[2] Fudan Univ, Adv Mat Lab, Shanghai 200433, Peoples R China
关键词
D O I
10.1021/ol7020143
中图分类号
O62 [有机化学];
学科分类号
070303 ; 081704 ;
摘要
A new multisignaling sensor based on rhodamine B with a ferrocene substituent (1) has been synthesized and has been shown to display extreme selectivity for Hg2+ over other metal ions. Multisignaling changes are observed through UV/vis absorption, fluorescence emission, and electrochemical measurements. Furthermore, by means of confocal laser scanning microscopy experiments, it is demonstrated that 1 can be used as a fluorescent probe for monitoring Hg2+ in living cells.
引用
收藏
页码:4729 / 4732
页数:4
相关论文
共 37 条
[1]   Highly selective chromogenic and redox or fluorescent sensors of Hg2+ in aqueous environment based on 1,4-disubstituted azines [J].
Caballero, A ;
Martínez, R ;
Lloveras, V ;
Ratera, I ;
Vidal-Gancedo, J ;
Wurst, K ;
Tárraga, A ;
Molina, P ;
Veciana, J .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (45) :15666-15667
[2]   Multifunctional linear triferrocene derivatives linked by oxidizable bridges:: Optical, electronic, and cation sensing properties [J].
Caballero, A ;
Tárraga, A ;
Velasco, MD ;
Espinosa, A ;
Molina, P .
ORGANIC LETTERS, 2005, 7 (15) :3171-3174
[3]   Azo 8-hydroxyquinoline benzoate as selective chromogenic chemosensor for Hg2+ and Cu2+ [J].
Cheng, Yun-Fei ;
Zhao, Da-Tong ;
Zhang, Meng ;
Liu, Zhi-Qiang ;
Zhou, Yi-Feng ;
Shu, Tian-Min ;
Li, Fu-You ;
Yi, Tao ;
Huang, Chun-Hui .
TETRAHEDRON LETTERS, 2006, 47 (36) :6413-6416
[4]   Reversible colorimetric probes for mercury sensing [J].
Coronado, E ;
Galán-Mascaros, JR ;
Martí-Gastaldo, C ;
Palomares, E ;
Durrant, JR ;
Vilar, R ;
Gratzel, M ;
Nazeeruddin, MK .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (35) :12351-12356
[5]   Signal ratio amplification via modulation of resonance energy transfer: Proof of principle in an emission ratiometric Hg(II) sensor [J].
Coskun, Ali ;
Akkaya, Engin U. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (45) :14474-14475
[6]   A long-wavelength fluorescent chemodosimeter selective for Cu(II) ion in water [J].
Dujols, V ;
Ford, F ;
Czarnik, AW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (31) :7386-7387
[7]   Small molecular chromogenic sensors for Hg2+:: A strong "push-pull" system exists after binding [J].
Fu, Yanyan ;
Li, Hongxiang ;
Hu, Wenping .
EUROPEAN JOURNAL OF ORGANIC CHEMISTRY, 2007, 2007 (15) :2459-2463
[8]   INORGANIC MERCURY (HG2+) TRANSPORT THROUGH LIPID BILAYER-MEMBRANES [J].
GUTKNECHT, J .
JOURNAL OF MEMBRANE BIOLOGY, 1981, 61 (01) :61-66
[9]   The chemical form of mercury in fish [J].
Harris, HH ;
Pickering, IJ ;
George, GN .
SCIENCE, 2003, 301 (5637) :1203-1203
[10]   Selective gold-nanoparticle-based "turn-on" fluorescent sensors for detection of mercury(II) in aqueous solution [J].
Huang, Chih-Ching ;
Chang, Huan-Tsung .
ANALYTICAL CHEMISTRY, 2006, 78 (24) :8332-8338