Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease

被引:166
作者
Bogert, L. W. J. [1 ]
Wesseling, K. H. [4 ]
Schraa, O. [5 ]
Van Lieshout, E. J. [2 ]
de Mol, B. A. J. M. [3 ,4 ]
van Goudoever, J. [5 ,6 ]
Westerhof, B. E. [5 ,6 ]
van Lieshout, J. J. [1 ,6 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Internal Med, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Intens Care, NL-1105 AZ Amsterdam, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Dept Cardiothorac Surg, NL-1105 AZ Amsterdam, Netherlands
[4] Eindhoven Univ Technol, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
[5] BMEYE BV, Amsterdam, Netherlands
[6] AMC Ctr Heart Failure Res, Lab Clin Cardiovasc Physiol, Amsterdam, Netherlands
关键词
RANDOMIZED CONTROLLED-TRIAL; STROKE VOLUME; BLOOD-PRESSURE; MECHANICAL VENTILATION; FLUID MANAGEMENT; HOSPITAL STAY; FINGER; THERMODILUTION; HUMANS; RECONSTRUCTION;
D O I
10.1111/j.1365-2044.2010.06511.x
中图分类号
R614 [麻醉学];
学科分类号
100217 [麻醉学];
摘要
P>Pulse contour methods determine cardiac output semi-invasively using standard arterial access. This study assessed whether cardiac output can be determined non-invasively by replacing the intra-arterial pressure input with a non-invasive finger arterial pressure input in two methods, Nexfin CO-trek (R) and Modelflow (R), in 25 awake patients after coronary artery bypass surgery. Pulmonary artery thermodilution cardiac output served as a reference. In the supine position, the mean (SD) differences between thermodilution cardiac output and Nexfin CO-trek were 0.22 (0.77) and 0.44 (0.81) l.min-1, for intra-arterial and non-invasive pressures, respectively. For Modelflow, these differences were 0.70 (1.08) and 1.80 (1.59) l.min-1, respectively. Similarly, in the sitting position, differences between thermodilution cardiac output and Nexfin CO-trek were 0.16 (0.78) and 0.34 (0.83), for intra-arterial and non-invasive arterial pressure, respectively. For Modelflow, these differences were 0.58 (1.11) and 1.52 (1.54) l.min-1, respectively. Thus, Nexfin CO-trek readings were not different from thermodilution cardiac output, for both invasive and non-invasive inputs. However, Modelflow readings differed greatly from thermodilution when using non-invasive arterial pressure input.
引用
收藏
页码:1119 / 1125
页数:7
相关论文
共 33 条
[1]
Non-invasive pulsatile arterial pressure and stroke volume changes from the human finger [J].
Bogert, LWJ ;
van Lieshout, JJ .
EXPERIMENTAL PHYSIOLOGY, 2005, 90 (04) :437-446
[2]
Reconstruction of brachial pressure from finger arterial pressure during orthostasis [J].
Bogert, LWJ ;
Harms, MPM ;
Pott, F ;
Secher, NH ;
Wesseling, KH ;
van Lieshout, JJ .
JOURNAL OF HYPERTENSION, 2004, 22 (10) :1873-1880
[3]
Reconstruction of brachial artery pressure from noninvasive finger pressure measurements [J].
Bos, WJW ;
vanGoudoever, J ;
vanMontfrans, GA ;
vandenMeiracker, AH ;
Wesseling, KH .
CIRCULATION, 1996, 94 (08) :1870-1875
[4]
Monitoring of peri-operative fluid administration by individualized goal-directed therapy [J].
Bundgaard-Nielsen, M. ;
Holte, K. ;
Secher, N. H. ;
Kehlet, H. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2007, 51 (03) :331-340
[5]
A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91
[6]
DIRECT BLOOD-PRESSURE MEASUREMENT - DYNAMIC-RESPONSE REQUIREMENTS [J].
GARDNER, RM .
ANESTHESIOLOGY, 1981, 54 (03) :227-236
[7]
Models of brachial to finger pulse wave distortion and pressure decrement [J].
Gizdulich, P ;
Prentza, A ;
Wesseling, KH .
CARDIOVASCULAR RESEARCH, 1997, 33 (03) :698-705
[8]
Validation of brachial artery pressure reconstruction from finger arterial pressure [J].
Guelen, Ilja ;
Westerhof, Berend E. ;
van der Sar, Gertrude L. ;
van Montfrans, Gert A. ;
Kiemeneij, Ferdinand ;
Wesseling, Karel H. ;
Bos, Willem Jan W. .
JOURNAL OF HYPERTENSION, 2008, 26 (07) :1321-1327
[9]
Continuous stroke volume monitoring by modelling flow from non-invasive measurement of arterial pressure in humans under orthostatic stress [J].
Harms, MPM ;
Wesseling, KH ;
Pott, F ;
Jenstrup, M ;
von Goudoever, J ;
Secher, NH ;
van Lieshout, JJ .
CLINICAL SCIENCE, 1999, 97 (03) :291-301
[10]
JANSEN JRC, 1986, INTENS CARE MED, V12, P71