Musculo-skeletal loading conditions at the hip during walking and stair climbing

被引:352
作者
Heller, MO
Bergmann, G
Deuretzbacher, G
Dürselen, L
Pohl, M
Claes, L
Haas, NP
Duda, GN
机构
[1] Humboldt Univ, Res Lab, Charite, Klinikum, D-13353 Berlin, Germany
[2] Univ Ulm, Inst Orthopaed Res & Biomech, Ulm, Germany
[3] Free Univ Berlin, Biomech Lab, D-1000 Berlin, Germany
[4] Univ Hamburg Hosp, Eppendorf, Germany
关键词
hip joint; loading; joint contact; muscle forces; simulation;
D O I
10.1016/S0021-9290(01)00039-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Musculo-skeletal loading plays an important role in the primary stability of joint replacements and in the biological processes involved in fracture healing. However, current knowledge of musculo-skeletal loading is still limited. In the past, a number of musculo-skeletal models have been developed to estimate loading conditions at the hip. So far, a cycle-to-cycle validation of predicted musculo-skeletal loading by in vivo measurements has not been possible. The aim of this study was to determine the musculo-skeletal loading conditions during walking and climbing stairs for a number of patients and compare these findings to in vivo data. Following total hip arthroplasty, four patients underwent gait analysis during walking and stair climbing. An instrumented femoral prosthesis enabled simultaneous measurement of in vivo hip contact forces. On the basis of CT and X-ray data. individual musculo-skeletal models of the lower extremity were developed for each patient. Muscle and joint contact forces were calculated using an optimization algorithm. The calculated peak hip contact forces both over- and under-estimated the measured forces. They differed by a mean of 12% during walking and 14% during stair climbing. For the first time, a cycle-to-cycle validation of predicted musculo-skeletal loading was possible For walking and climbing stairs in several patients. In all cases, the comparison of in vivo measured and calculated hip contact forces showed good agreement. Thus, the authors consider the presented approach as a useful means to determine valid conditions for the analysis of prosthesis loading, bone modeling or remodeling processes around implants and fracture stability following internal fixation. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:883 / 893
页数:11
相关论文
共 44 条
  • [1] PHYSIOLOGICAL CONSIDERATIONS OF MUSCLE FORCE THROUGH THE ELBOW JOINT
    AN, KN
    KAUFMAN, KR
    CHAO, EYS
    [J]. JOURNAL OF BIOMECHANICS, 1989, 22 (11-12) : 1249 - 1256
  • [2] Andrews J. G., 1974, Kinesiology, V4, P32, DOI [10.1097/00152193-197401000-00014, DOI 10.1097/00152193-197401000-00014]
  • [3] HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS
    BERGMANN, G
    GRAICHEN, F
    ROHLMANN, A
    [J]. JOURNAL OF BIOMECHANICS, 1993, 26 (08) : 969 - 990
  • [4] Hip contact forces and gait patterns from routine activities
    Bergmann, G
    Deuretzbacher, G
    Heller, M
    Graichen, F
    Rohlmann, A
    Strauss, J
    Duda, GN
    [J]. JOURNAL OF BIOMECHANICS, 2001, 34 (07) : 859 - 871
  • [5] MULTICHANNEL STRAIN-GAUGE TELEMETRY FOR ORTHOPEDIC IMPLANTS
    BERGMANN, G
    GRAICHEN, F
    SIRAKY, J
    JENDRZYNSKI, H
    ROHLMANN, A
    [J]. JOURNAL OF BIOMECHANICS, 1988, 21 (02) : 169 - 176
  • [6] IS STAIRCASE WALKING A RISK FOR THE FIXATION OF HIP IMPLANTS
    BERGMANN, G
    GRAICHEN, F
    ROHLMANN, A
    [J]. JOURNAL OF BIOMECHANICS, 1995, 28 (05) : 535 - 553
  • [7] Brand R A, 1994, J Arthroplasty, V9, P45, DOI 10.1016/0883-5403(94)90136-8
  • [8] Brand R. A., 1989, T ORS, V1, P96
  • [9] A MODEL OF LOWER-EXTREMITY MUSCULAR ANATOMY
    BRAND, RA
    CROWNINSHIELD, RD
    WITTSTOCK, CE
    PEDERSEN, DR
    CLARK, CR
    VANKRIEKEN, FM
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1982, 104 (04): : 304 - 310
  • [10] THE SENSITIVITY OF MUSCLE FORCE PREDICTIONS TO CHANGES IN PHYSIOLOGICAL CROSS-SECTIONAL AREA
    BRAND, RA
    PEDERSEN, DR
    FRIEDERICH, JA
    [J]. JOURNAL OF BIOMECHANICS, 1986, 19 (08) : 589 - 596