Microbubble responses to a similar mechanical index with different real-time perfusion imaging techniques

被引:9
作者
Porter, TR [1 ]
Oberdorfer, J
Rafter, P
Lof, J
Xie, F
机构
[1] Univ Nebraska, Med Ctr, Nebraska Med Ctr, Dept Internal Med,Sect Cardiol, Omaha, NE 68198 USA
[2] Philips Med Syst, Andover, MA USA
关键词
mechanical index; pulse sequence schemes; ultrasound; microbubbles;
D O I
10.1016/S0301-5629(03)00900-1
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The purpose of this study was to determine differences in contrast enhancement and microbubble destruction rates with current commercially available low-mechanical index (MI) real-time perfusion imaging modalities. A tissue-mimicking phantom was developed that had vessels at 3 cm (near field) and 9 cm (far field) from a real-time transducer. Perfluorocarbon-exposed sonicated dextrose albumin microbubbles (PESDA) were injected proximal to a mixing chamber, and then passed through these vessels while the region was insonified with either pulses of alternating polarity with pulse inversion Doppler (PID) or pulses of alternating amplitude by power modulation (PM) at MIs of 0.1, 0.2 and 0.3. Effluent microbubble concentration, contrast intensity and the slope of digital contrast intensity vs. time were measured. Our results demonstrated that microbubble destruction already occurs with PID at an MI of 0.1. Contrast intensity seen with PID was less than with PM. Therefore, differences in contrast enhancement and microbubble destruction rates occur at a similar MI setting when using different real-time pulse sequence schemes. (C) 2003 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:1187 / 1192
页数:6
相关论文
共 8 条
[1]   Threshold of fragmentation for ultrasonic contrast agents [J].
Chomas, JE ;
Dayton, P ;
May, D ;
Ferrara, K .
JOURNAL OF BIOMEDICAL OPTICS, 2001, 6 (02) :141-150
[2]   Mechanisms of contrast agent destruction [J].
Chomas, JE ;
Dayton, P ;
Allen, J ;
Morgan, K ;
Ferrara, KW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2001, 48 (01) :232-248
[3]  
Merritt CR, 2000, RADIOLOGY, V217, P395
[4]   Combined assessment of myocardial perfusion and regional left ventricular function by analysis of contrast-enhanced power modulation images [J].
Mor-Avi, V ;
Caiani, EG ;
Collins, KA ;
Korcarz, CE ;
Bednarz, JE ;
Lang, RM .
CIRCULATION, 2001, 104 (03) :352-357
[5]   Real-time perfusion imaging with low mechanical index pulse inversion Doppler imaging [J].
Porter, TR ;
Xie, F ;
Silver, M ;
Kricsfeld, D ;
O'Leary, E .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (03) :748-753
[6]  
PORTER TR, 2001, ACC CURR J REV, V10, P43
[7]   Pulse inversion Doppler: A new method for detecting nonlinear echoes from microbubble contrast agents [J].
Simpson, DH ;
Chin, CT ;
Burns, PN .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (02) :372-382
[8]   The impact of emission power on the destruction of echo contrast agents and on the origin of tissue harmonic signals using power pulse-inversion imaging [J].
Tiemann, K ;
Veltmann, C ;
Ghanem, A ;
Lohmaier, S ;
Bruce, M ;
Kuntz-Hehner, S ;
Pohl, C ;
Ehlgen, A ;
Schlosser, T ;
Omran, H ;
Becher, H .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (11) :1525-1533