A comparison of plates with and without locking screws in a calcaneal fracture model

被引:66
作者
Richter, M [1 ]
Gosling, T [1 ]
Zech, S [1 ]
Allami, M [1 ]
Geerling, J [1 ]
Droste, P [1 ]
Krettek, C [1 ]
机构
[1] Hannover Med Sch, Trauma Dept, D-30625 Hannover, Germany
关键词
calcaneal fracture; experimental testing; fracture model; locked screw; plate fixation;
D O I
10.1177/107110070502600407
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: We compared different plates in an experimental calcaneal fracture model under biocompatible loading. Methods: Four plates were tested: a plate without locked screws (Synthes), and three different plates with locked screws (Newdeal, Darco, Synthes). Synthetic calcanei (Sawbone) were osteotomized to create a fracture model, and the plates were fixed onto them. Seven specimens for each plate model were subjected to cyclic loading (preload 20 N, 1,000 cycles with 800 N, 0.75 mm/s), and load to failure (0.75 mm/s). Motion, forces, plastic deformation of the plate, and consequent depression of the posterior joint facet were analyzed. Results: During cyclic loading, all plates with locked screws showed statistically significant lower displacement in the primary loading direction than the plates without locked screws. Mean values (mm) of maximal displacements for each plate during cyclic loading were as follows: Synthes, 3.5; Darco, 4.5; Newdeal, 5.0; Synthes without locked screws, 7.5; (p < 0.001). No statistically significant differences between the plates were found in relation to loads to failure and corresponding displacement. Conclusion: This is the first biomechanical study to assess the stability of different plates currently in use in our practice for the fixation of calcaneal fractures. Our results showed that plates with locked screws provided greater stability during cyclic loading than the plate without locked screws.
引用
收藏
页码:309 / 319
页数:11
相关论文
共 16 条
[1]
Operative compared with nonoperative treatment of displacedintra-articular calcaneal fractures - A prospective, randomized, controlled multicenter trial [J].
Buckley, R ;
Tough, S ;
McCormack, R ;
Pate, G ;
Leighton, R ;
Petrie, D ;
Galpin, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (10) :1733-1744
[2]
Internal fixation of experimental intraarticular calcaneal fractures: A biomechanical analysis of two fixation methods [J].
Carr, JB ;
Tigges, RG ;
Wayne, JS ;
Earll, M .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (06) :425-428
[3]
ESSEXLOPRESTI P, 1993, CLIN ORTHOP RELAT R, P3
[4]
The use of subtalar arthroscopy in open reduction and internal fixation of intra-articular calcaneal fractures [J].
Gavlik, JM ;
Rammelt, S ;
Zwipp, H .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 (01) :63-71
[5]
Comparison of the trabecular architecture and the isostatic stress flow in the human calcaneus [J].
Gefen, A ;
Seliktar, R .
MEDICAL ENGINEERING & PHYSICS, 2004, 26 (02) :119-129
[6]
Proximal humeral fractures: how stiff should an implant be? A comparative mechanical study with new implants in human specimens [J].
Lill, H ;
Hepp, P ;
Korner, J ;
Kassi, JP ;
Verheyden, AP ;
Josten, C ;
Duda, GN .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2003, 123 (2-3) :74-81
[7]
Lin PP, 1998, CLIN ORTHOP RELAT R, P194
[8]
Biomechanical comparison of ankle arthrodesis techniques: Crossed screws vs. blade plate [J].
Nasson, S ;
Shuff, C ;
Palmer, D ;
Owen, J ;
Wayne, J ;
Carr, J ;
Adelaar, R ;
May, D .
FOOT & ANKLE INTERNATIONAL, 2001, 22 (07) :575-580
[9]
Rammelt S, 2001, J BONE JOINT SURG AM, V83A, P1438, DOI 10.2106/00004623-200109000-00040
[10]
Plantar impact causing midfoot fractures result in higher forces in Chopart's joint than in the ankle joint [J].
Richter, M ;
Wippermann, B ;
Thermann, H ;
Schroeder, G ;
Otte, D ;
Troeger, HD ;
Krettek, C .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2002, 20 (02) :222-232