Quality of reporting of diagnostic accuracy studies

被引:100
作者
Smidt, N
Rutjes, AWS
van der Windt, DAWM
Ostelo, RWJG
Reitsma, JB
Bossuyt, PM
Bouter, LM
de Vet, HCW
机构
[1] Free Univ Amsterdam, Med Ctr, Inst Res Extramural Med, NL-1081 BT Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Clin Epidemiol & Biostat, NL-1105 AZ Amsterdam, Netherlands
关键词
D O I
10.1148/radiol.2352040507
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate quality of reporting in diagnostic accuracy articles published in 2000 in journals with impact factor of at least 4 by using items of Standards for Reporting of Diagnostic Accuracy (STARD) statement published later in 2003. MATERIALS AND METHODS: English-language articles on primary diagnostic accuracy studies in 2000 were identified with validated search strategy in MEDLINE. Articles published in journals with impact factor of 4 or higher that regularly publish articles on diagnostic accuracy were selected. Two independent reviewers evaluated quality of reporting by using STARD statement, which consists of 25 items and encourages use of a flow diagram. Total STARD score for each article was calculated by summing number of reported items. Subgroup analyses were performed for study design (case-control or cohort study) by using Student t tests for continuous outcomes and chi(2) tests for dichotomous outcomes. RESULTS: Included were 124 articles published in 2000 in 12 journals: 33 case-control and 91 cohort studies. Only 41% of articles (51 of 124) reported on more than 50% of STARD items, while no articles reported on more than 80%. A flow chart was presented in two articles. Assessment of reporting on individual items of STARD statement revealed wide variation, with some items described in 11% of articles and others in 92%. Mean STARD score (0-25 points available) was 11.9 (range, 3.5-19.5). Mean difference in STARD score between cohort studies and case-control studies was 1.53 (95% confidence interval: 0.24, 2.82). CONCLUSION: Quality of reporting in diagnostic accuracy articles published in 2000 is less than optimal, even in journals with high impact factor. Authors, editors, and reviewers should pay more attention to reporting by checking STARD statement items and including a flow diagram to represent study design and patient flow. (C) RSNA, 2005.
引用
收藏
页码:347 / 353
页数:7
相关论文
共 15 条
[1]  
Altman DG, 1996, BRIT MED J, V313, P570
[2]   The STARD statement for reporting studies of diagnostic accuracy: Explanation and elaboration [J].
Bossuyt, PM ;
Reitsma, JB ;
Bruns, DE ;
Gatsonis, CA ;
Glasziou, PP ;
Irwig, LM ;
Moher, D ;
Rennie, D ;
de Vet, HCW ;
Lijmer, JG .
CLINICAL CHEMISTRY, 2003, 49 (01) :7-18
[3]   Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD initiative [J].
Bossuyt, PM ;
Reitsma, JB ;
Bruns, DE ;
Gatsonis, CA ;
Glasziou, PP ;
Irwig, LM ;
Lijmer, JG ;
Moher, D ;
Rennie, D ;
de Vet, HCW .
RADIOLOGY, 2003, 226 (01) :24-28
[4]  
Bruns DE, 2000, CLIN CHEM, V46, P893
[5]   Publications on diagnostic test evaluation in family medicine journals:: an optimal search strategy [J].
Devillé, WLJM ;
Bezemer, PD ;
Bouter, LM .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2000, 53 (01) :65-69
[6]   The test of Lasegue -: Systematic review of the accuracy in diagnosing herniated discs [J].
Devillé, WLJM ;
van der Windt, DAWM ;
Dzaferagic, A ;
Bezemer, PD ;
Bouter, LM .
SPINE, 2000, 25 (09) :1140-1147
[7]   Value of flow diagrams in reports of randomized controlled trials [J].
Egger, M ;
Jüni, P ;
Bartlett, C .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 285 (15) :1996-1999
[8]   Assessment of the accuracy of diagnostic tests: the cross-sectional study [J].
Knottnerus, JA ;
Muris, JW .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2003, 56 (11) :1118-1128
[9]   Empirical evidence of design-related bias in studies of diagnostic tests [J].
Lijmer, JG ;
Mol, BW ;
Heisterkamp, S ;
Bonsel, GJ ;
Prins, MH ;
van der Meulen, JHP ;
Bossuyt, PMM .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 282 (11) :1061-1066
[10]   Use of the CONSORT statement and quality of reports of randomized trials - A comparative before-and-after evaluation [J].
Moher, D ;
Jones, A ;
Lepage, L .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 285 (15) :1992-1995