Continuous-flow, on-line monitoring of biospecific interactions using electrospray mass spectrometry

被引:29
作者
Hogenboom, AC [1 ]
de Boer, AR [1 ]
Derks, RJE [1 ]
Irth, H [1 ]
机构
[1] Free Univ Amsterdam, Dept Analyt Chem & Appl Spect, Div Chem, Fac Sci, NL-1081 HV Amsterdam, Netherlands
关键词
D O I
10.1021/ac010026o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A continuous-flow analytical screening system is presented using electrospray mass spectrometry to measure the interaction of biologically active compounds with soluble affinity proteins. The biochemical detection system is based on a solution-phase, homogeneous assay. In a first step, compounds to be screened (e.g., biotinylated compounds, concentration range 10-1000 nmol/L) are injected into a continuous-flow reaction system and allowed to react with the affinity protein (e.g., streptavidin, concentration range 3-48 nmol/L). Subsequently, a reporter ligand (fluorescein-labeled biotin 96 nmol/L) is added to saturate the remaining free binding sites of the affinity protein and the concentration of unbound reporter ligand is measured using electrospray MS in the selected-ion monitoring mode. The presence of active compounds in the sample results in an increase of the concentration of unbound reporter ligands. The feasibility of a homogeneous MS-based biochemical assay is demonstrated using streptavidin/biotin and anti-digoidgenin/digoxin as model systems. Compared to radioactive or fluorescence-based biochemical assays, the present assay format does not require the synthesis and purification of labels. Various analytical conditions were investigated to determine the ability of MS to measure the biochemical interactions. The availability of a single ligand that can be detected at 10-50 nmol/L concentrations by electrospray MS is sufficient to set up the biochemical assay. For the biospecific interactions studies, detection limits of 10-100 nmol/L were obtained.
引用
收藏
页码:3816 / 3823
页数:8
相关论文
共 45 条
[1]   Determination of carbendazim in soil and lake water by immunoaffinity extraction and coupled-column liquid chromatography tandem mass spectrometry [J].
Bean, KA ;
Henion, JD .
JOURNAL OF CHROMATOGRAPHY A, 1997, 791 (1-2) :119-126
[2]   Determining affinity-selected ligands and estimating binding affinities by online size exclusion chromatography liquid chromatography-mass spectrometry [J].
Blom, KF ;
Larsen, BS ;
McEwen, CN .
JOURNAL OF COMBINATORIAL CHEMISTRY, 1999, 1 (01) :82-90
[3]   Affinity capillary electrophoresis in biomolecular recognition [J].
Chu, YH ;
Cheng, CC .
CELLULAR AND MOLECULAR LIFE SCIENCES, 1998, 54 (07) :663-683
[4]   Iterative size-exclusion chromatography coupled with liquid chromatographic mass spectrometry to enrich and identify tight-binding ligands from complex mixtures [J].
Davis, RG ;
Anderegg, RJ ;
Blanchard, SG .
TETRAHEDRON, 1999, 55 (39) :11653-11667
[5]   ELECTROSPRAY MASS-SPECTROMETRIC ANALYSIS OF THE DOMAINS OF A LARGE ENZYME - OBSERVATION OF THE OCCUPIED COBALAMIN-BINDING DOMAIN AND REDEFINITION OF THE CARBOXYL-TERMINUS OF METHIONINE SYNTHASE [J].
DRUMMOND, JT ;
LOO, RRO ;
MATTHEWS, RG .
BIOCHEMISTRY, 1993, 32 (36) :9282-9289
[6]   ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY OF BIOTIN BINDING TO STREPTAVIDIN [J].
ECKART, K ;
SPIESS, J .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1995, 6 (10) :912-919
[7]   BIOSPECIFIC DETECTION IN LIQUID-CHROMATOGRAPHY [J].
EMNEUS, J ;
MARKOVARGA, G .
JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) :191-243
[8]   IMMUNOAFFINITY PRECOLUMN FOR SELECTIVE SAMPLE PRETREATMENT IN COLUMN LIQUID-CHROMATOGRAPHY - IMMUNOSELECTIVE DESORPTION [J].
FARJAM, A ;
BRUGMAN, AE ;
SOLDAAT, A ;
TIMMERMAN, P ;
LINGEMAN, H ;
DEJONG, GJ ;
FREI, RW ;
BRINKMAN, UAT .
CHROMATOGRAPHIA, 1991, 31 (9-10) :469-477
[9]   OBSERVATION OF NONCOVALENT ENZYME SUBSTRATE AND ENZYME PRODUCT COMPLEXES BY ION-SPRAY MASS-SPECTROMETRY [J].
GANEM, B ;
LI, YT ;
HENION, JD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (20) :7818-7819
[10]   DETECTION OF NONCOVALENT RECEPTOR LIGAND COMPLEXES BY MASS-SPECTROMETRY [J].
GANEM, B ;
LI, YT ;
HENION, JD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (16) :6294-6296