Copper-selective PVC membrane electrodes based on salens as carriers

被引:85
作者
Fakhari, AR [1 ]
Raji, TA
Naeimi, H
机构
[1] Shahid Beheshti Univ, Dept Chem, Tehran, Iran
[2] Kashan Univ, Dept Chem, Kashan, Iran
关键词
copper ion-selective; PVC membrane; salen; potentiometry;
D O I
10.1016/j.snb.2004.05.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Copper(II) selective sensors have been fabricated from polyvinyl chloride (PVC) matrix membranes containing carriers, 2,2-[1,2-ethandiyl-bis(nitrilomethylidine)-bis]meta cresole(l),2,2-[1,2-ethandiyl-bis(nitrilomethylidine)-bis]para cresole(II) and 2,2'-[1,2-ethandiyl-bis(nitritomethylidine)-bis]ortho cresole(III) as ionophores, dibutyl phthalate (DBP), benzyl acetate (BA), acetophenone (AP) and o-nitrophenyl octyl ether (NPOE) as plasticizing solvent mediators and sodium tetraphenylborate (STPB) and oleic acid (OA) as additives. Best performance was exhibited by the membrane having a composition ionophore (SALEN):PVC:NPOE:OA in the ratio of 4:31:55:10 (w/w). These membranes give a linear potential response in the concentration range (1.0 x 10(-5) to 1.0 x 10(-1) M) with a Nernstian slope of 29.2 +/- 0.3, 29.7 +/- 0.3 and 28.2 +/- 0.3 mV/decade of Cu2+ and limits of detection are 3.6 x 10(-6) M, 3.1 x 10(-6) M and 6.3 x 10-6 M for salen (1), (11) and (111), respectively. It has a very short response time, less than 10 s, and can be used for at least 9 weeks without any divergence in potential. The copper (11) selective electrode exhibited very good selectivities with respect to alkali, alkali earth and some transition metal ions and could be used in a pH range 3.5-6.5. It was successfully applied for the direct determination of copper in sample of brass and a sample of Wilson's patient's urine. This electrode was also used as an indicator electrode in titration of Cu2+ with EDTA. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:317 / 323
页数:7
相关论文
共 60 条
[1]   Copper(II)-selective membrane electrode based on a recently synthesized naphthol-derivative Schiff's base [J].
Alizadeh, N ;
Ershad, S ;
Naeimi, H ;
Sharghi, H ;
Shamsipur, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (06) :511-515
[2]   LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS [J].
AMMANN, D ;
PRETSCH, E ;
SIMON, W ;
LINDNER, E ;
BEZEGH, A ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) :119-129
[3]   PROPERTIES OF PVC BASED MEMBRANES USED IN ION-SELECTIVE ELECTRODES [J].
ARMSTRONG, RD ;
HORVAI, G .
ELECTROCHIMICA ACTA, 1990, 35 (01) :1-7
[4]   Salan complexes of the group 12, 13 and 14 elements [J].
Atwood, DA .
COORDINATION CHEMISTRY REVIEWS, 1997, 165 :267-296
[5]   OPTIMUM COMPOSITION OF NEUTRAL CARRIER BASED PH ELECTRODES [J].
BAKKER, E ;
XU, AP ;
PRETSCH, E .
ANALYTICA CHIMICA ACTA, 1994, 295 (03) :253-262
[6]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[7]   The influence of imine structure, catalyst structure and reaction conditions on the enantioselectivity of the alkylation of alanine methyl ester imines catalyzed by Cu(ch-salen) [J].
Belokon', YN ;
Davies, RG ;
Fuentes, JA ;
North, M ;
Parsons, T .
TETRAHEDRON LETTERS, 2001, 42 (45) :8093-8096
[8]   Chiral salen-metal complexes as novel catalysts for the asymmetric synthesis of α-amino acids under phase transfer catalysis conditions [J].
Belokon, YN ;
North, M ;
Churkina, TD ;
Ikonnikov, NS ;
Maleev, VI .
TETRAHEDRON, 2001, 57 (13) :2491-2498
[9]   A practical asymmetric synthesis of α-methyl α-amino acids using a chiral Cu-salen complex as a phase transfer catalyst [J].
Belokon', YN ;
Davies, RG ;
North, M .
TETRAHEDRON LETTERS, 2000, 41 (37) :7245-7248
[10]  
Calligaris M., 1987, COMPREHENSIVE COORDI, V2