摘要
Purpose: Our goal was to evaluate the influence of spatially heterogeneous background activity on ''hot object'' quantitation in brain emission CT. Method: We studied the effects of spatially heterogeneous background activity on hot object quantitative recovery in simulations of both spheres and realistic brain distributions (utilizing human MRI data). Results: Significant underestimation of object activity concentration was seen for both cortical and subcortical hot objects, with increasing underestimation for increasing hot object/surrounding gray matter contrast. Significant ''spill-in'' of counts from surrounding activity was present. Conclusion: Hot objects are significantly influenced by both ''spill-out'' and ''spill-in.'' Qualitative and quantitative analyses of such objects must explicitly consider both spill-out and spill-in; this implies a correction scheme that goes beyond simple division of the observed value by a conventional recovery coefficient.
引用
收藏
页码:680 / 687
页数:8
相关论文
共 12 条
[1]   QUANTITATION OF THE HUMAN BASAL GANGLIA WITH POSITRON EMISSION TOMOGRAPHY - A PHANTOM STUDY OF THE EFFECT OF CONTRAST AND AXIAL POSITIONING [J].
BENDRIEM, B ;
DEWEY, SL ;
SCHLYER, DJ ;
WOLF, AP ;
VOLKOW, ND .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (02) :216-222
[2]   AN APPROXIMATION FORMULA FOR THE VARIANCE OF PET REGION-OF-INTEREST VALUES [J].
CARSON, RE ;
YAN, Y ;
DAUBEWITHERSPOON, ME ;
FREEDMAN, N ;
BACHARACH, SL ;
HERSCOVITCH, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (02) :240-250
[3]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .1. EFFECT OF OBJECT SIZE [J].
HOFFMAN, EJ ;
HUANG, SC ;
PHELPS, ME .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (03) :299-308
[4]   ANALYSIS OF EMISSION TOMOGRAPHIC SCAN DATA - LIMITATIONS IMPOSED BY RESOLUTION AND BACKGROUND [J].
KESSLER, RM ;
ELLIS, JR ;
EDEN, M .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (03) :514-522
[5]  
KOJIMA A, 1989, J NUCL MED, V30, P508
[6]   3D SIMULATION OF PET BRAIN IMAGES USING SEGMENTED MRI DATA AND POSITRON TOMOGRAPH CHARACTERISTICS [J].
MA, Y ;
KAMBER, M ;
EVANS, AC .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1993, 17 (4-5) :365-371
[7]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .5. PHYSICAL-ANATOMICAL EFFECTS [J].
MAZZIOTTA, JC ;
PHELPS, ME ;
PLUMMER, D ;
KUHL, DE .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (05) :734-743
[8]  
MELTZER CC, 1994, J NUCL MED, V35, pP197
[9]  
MUELLERGAERTNER HW, 1992, J CEREB BLOOD FLOW M, V12, P571
[10]   CONCENTRATION RECOVERY FOR SPECT CNS DOPAMINE-RECEPTOR STUDIES FOR MONKEYS [J].
SHAO, LX ;
BILLINGS, J ;
PFEIFFER, N ;
KUNG, HF .
MEDICAL PHYSICS, 1994, 21 (05) :675-681