Experimental tests of EEG source localization accuracy in spherical head models

被引:55
作者
Cuffin, BN
Schomer, DL
Ives, JR
Blume, H
机构
[1] Beth Israel Deaconess Med Ctr, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA 02215 USA
关键词
EEG; source localization; depth electrodes; inverse solutions; spherical head model; dipoles;
D O I
10.1016/S1388-2457(00)00488-0
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objectives: The locations of electrical sources in the brain can be calculated using EEG data. However, the accuracy of these calculations is not well known because it is usually not possible to compare calculated source locations with actual locations since little accurate location information is available about most sources in the brain. Methods: In this study, sources at known locations are created by injecting current into electrodes implanted in the brains of human subjects. The locations of the implanted and scalp EEG electrodes are determined from CTs. The EEG signals produced by these dipolar sources are used to calculate source locations in spherical head models containing brain, skull, and scalp layers. The brain and scalp layers have the same electrical conductivity while 3 different skull conductivity ratios of 1/80th, 1/40th, and 1/20th of brain and scalp conductivity are used. Localization errors have been determined for 177 sources in 13 subjects. Results: An average localization error of 10.6 (SD = 5.5) mm for all 177 source was obtained for a skull conductivity ratio of 1/40. The average errors for the other ratios an only a few millimeters larger. The average localization error for 108 sources at superior locations in the brain is 9.2 (4.3) mm. The average error for 69 inferior location sources is 12.8 (6.2) mm. There are no significant differences in localization accuracy for deep and superficial sources. Conclusions: These results indicate that the best average localization that can be achieved using a spherical head model is approximately 10 mm. More realistic head models will be required for greater localization accuracy. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 8 条
  • [1] LOCATION OF SOURCES OF EVOKED SCALP POTENTIALS - CORRECTIONS FOR SKULL AND SCALP THICKNESSES
    ARY, JP
    KLEIN, SA
    FENDER, DH
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (06) : 447 - 452
  • [2] TESTS OF EEG LOCALIZATION ACCURACY USING IMPLANTED SOURCES IN THE HUMAN BRAIN
    CUFFIN, BN
    COHEN, D
    YUNOKUCHI, K
    MANIEWSKI, R
    PURCELL, C
    COSGROVE, GR
    IVES, J
    KENNEDY, J
    SCHOMER, D
    [J]. ANNALS OF NEUROLOGY, 1991, 29 (02) : 132 - 138
  • [3] CUFFIN BN, 2000, IN PRESS J CLIN NEUR
  • [4] Accuracy of EEG dipole source localization using implanted sources in the human brain
    Krings, T
    Chiappa, KH
    Cuffin, BN
    Cochius, JI
    Connolly, S
    Cosgrove, GR
    [J]. CLINICAL NEUROPHYSIOLOGY, 1999, 110 (01) : 106 - 114
  • [5] PRESS WH, 1989, NUMERICAL RECIPES, P289
  • [6] AN IMPROVED METHOD FOR LOCALIZING ELECTRIC BRAIN DIPOLES
    SALU, Y
    COHEN, LG
    ROSE, D
    SATO, S
    KUFTA, C
    HALLETT, M
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (07) : 699 - 705
  • [7] A RELIABLE METHOD FOR LOCALIZING DEEP INTRACRANIAL SOURCES OF THE EEG
    SMITH, DB
    SIDMAN, RD
    FLANIGIN, H
    HENKE, J
    LABINER, D
    [J]. NEUROLOGY, 1985, 35 (12) : 1702 - 1707
  • [8] THE INFLUENCE OF MODEL PARAMETERS ON EEG MEG SINGLE DIPOLE SOURCE ESTIMATION
    STOK, CJ