Impaction bone grafting with freeze-dried irradiated bone. Part II. Changes in stiffness and compactness of morselized grafts - Experiments in cadavers

被引:35
作者
Cornu, O [1 ]
Bavadekar, A
Godts, B
Van Tomme, J
Delloye, C
Banse, X
机构
[1] Catholic Univ Louvain, Orthopaed Res Lab, B-3000 Louvain, Belgium
[2] Royal Mil Acad, Dept Civil Engn, Brussels, Belgium
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 2003年 / 74卷 / 05期
关键词
D O I
10.1080/00016470310017947
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In the technique of impaction bone grafting, implant stability depends on the mechanical properties of the impacted morselized grafts. Although the procedure is usually performed with fresh-frozen femoral heads, there is still some concern about their supply and safety. Bone processing is a potential solution, but the mechanical properties of this material during and after impaction need to be determined. We used 6 osteoarthrotic femoral heads to prepare two paired batches of morselized bone. One batch was morselized and frozen. The other batch was chemically treated, morselized, freeze-dried and then gamma-irradiated. We impacted 18 samples from each batch in a contained cylinder. Freeze-dried bone grafts were tested after 30 minutes of rehydration. The changes in the compactness and stiffness of the material were monitored during the impaction. The compaction of the freeze-dried bone was faster than that of their fresh-frozen control. The maximal stiffness reached by both materials was the same (55 MPa), but the freeze-dried grafts required three to four times fewer impactions to achieve that stiffness. After 3, 10 and 50 impactions the freeze-dried bone was stiffer than the fresh-frozen bone. As it is easier to impact, the freeze-dried bone may be mechanically more efficient than the fresh-frozen bone in surgical conditions. Moreover, the processed bone meets the highest safety standards, as regards the risk of disease transmission.
引用
收藏
页码:553 / 558
页数:6
相关论文
共 21 条
[1]
COMPRESSIVE MECHANICAL-PROPERTIES OF HUMAN CANCELLOUS BONE AFTER GAMMA-IRRADIATION [J].
ANDERSON, MJ ;
KEYAK, JH ;
SKINNER, HB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (05) :747-752
[2]
Stiffness and compactness of morselized grafts during impaction - An in vitro study with human femoral heads [J].
Bavadekar, A ;
Cornu, O ;
Godts, B ;
Delloye, C ;
Van Tomme, J ;
Banse, X .
ACTA ORTHOPAEDICA SCANDINAVICA, 2001, 72 (05) :470-476
[3]
COMPRESSIVE BEHAVIOR OF BONE AS A 2-PHASE POROUS STRUCTURE [J].
CARTER, DR ;
HAYES, WC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (07) :954-962
[4]
Effect of freeze-drying and gamma irradiation on the mechanical properties of human cancellous bone [J].
Cornu, O ;
Banse, X ;
Docquier, PL ;
Luyckx, S ;
Delloye, C .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2000, 18 (03) :426-431
[5]
TIBIAL TUBERCLE ELEVATION WITH BONE-GRAFTS - A COMPARATIVE-STUDY OF AUTOGRAFT AND ALLOGRAFT [J].
CORNU, OH ;
DEHALLEUX, J ;
BANSE, X ;
DELLOYE, C .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1995, 114 (06) :324-329
[6]
Delloye C, 1987, Acta Orthop Belg, V53, P2
[7]
*EAMST, 1997, COMM STAND MUSC TISS
[8]
ALLOGRAFT VERSUS AUTOGRAFT BONE IN IDIOPATHIC SCOLIOSIS SURGERY - A MULTIVARIATE STATISTICAL-ANALYSIS [J].
FABRY, G .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1991, 11 (04) :465-468
[9]
STUDIES ON THE ANTIGENICITY OF BONE .2. DONOR-SPECIFIC ANTI-HLA ANTIBODIES IN HUMAN RECIPIENTS OF FREEZE-DRIED ALLOGRAFTS [J].
FRIEDLAENDER, GE ;
STRONG, DM ;
SELL, KW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (01) :107-112
[10]
Supply and demand of bone allograft for revision hip surgery in Scotland [J].
Galea, G ;
Kopman, D ;
Graham, BJM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (04) :595-599