Effect of freeze-drying and gamma irradiation on the mechanical properties of human cancellous bone

被引:113
作者
Cornu, O [1 ]
Banse, X [1 ]
Docquier, PL [1 ]
Luyckx, S [1 ]
Delloye, C [1 ]
机构
[1] Univ Catholique Louvain, Orthopaed Res Lab, B-1200 Brussels, Belgium
关键词
D O I
10.1002/jor.1100180314
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Freeze-drying and gamma irradiation are commonly used for preservation and sterilization in bone banking. The cumulative effects of preparation and sterilization of cancellous graft material have not been adequately studied, despite the clinical importance of graft material in orthopaedic surgery. Taking benefit from the symmetry of the left and right femoral heads, the influence of lipid extraction followed by freeze-drying of a femoral head and a final 25-kGy gamma irradiation was determined, with the nonirradiated. nonprocessed counterpart as the control. Five hundred and fifty-six compression tests were performed (137 pairs for the first treatment and 141 pairs for the second). Mechanical tests were performed after 30 minutes of rehydration in saline solution. Freeze-dried femoral heads that had undergone lipid extraction experienced reductions of 18.9 and 20.2% in ultimate strength and stiffness, respectively. Unexpectedly, the work to failure did not decrease after this treatment. The addition of gamma irradiation resulted in a mean drop of 42.5% in ultimate strength. Stiffness of the processed bone was not modified by the final irradiation, with an insignificant drop of 24%, whereas work to failure was reduced by a mean of 71.8%. Freeze-dried bone was a bit less strong and stiff than its frozen control. Tts work to failure was not reduced, due to more deformation in the nonlinear domain, and it was not brittle after 30 minutes of rehydration. Final irradiation of the freeze-dried bone weakened its mechanical resistance, namely by the loss of its capacity to absorb the energy tin a plastic way) and a subsequent greater brittleness.
引用
收藏
页码:426 / 431
页数:6
相关论文
共 21 条
[1]   COMPRESSIVE MECHANICAL-PROPERTIES OF HUMAN CANCELLOUS BONE AFTER GAMMA-IRRADIATION [J].
ANDERSON, MJ ;
KEYAK, JH ;
SKINNER, HB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (05) :747-752
[2]   Comparative left-right mechanical testing of cancellous bone from normal femoral heads [J].
Banse, X ;
Delloye, C ;
Cornu, O ;
Bourgois, R .
JOURNAL OF BIOMECHANICS, 1996, 29 (10) :1247-1253
[3]  
BRIGHT RW, 1978, T ORTHOP RES SOC, V3, P210
[4]   EVALUATION OF ORTHOGONAL MECHANICAL-PROPERTIES AND DENSITY OF HUMAN TRABECULAR BONE FROM THE MAJOR METAPHYSEAL REGIONS WITH MATERIALS TESTING AND COMPUTED-TOMOGRAPHY [J].
CIARELLI, MJ ;
GOLDSTEIN, SA ;
KUHN, JL ;
CODY, DD ;
BROWN, MB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (05) :674-682
[5]  
CONRAD EU, 1993, CLIN ORTHOP RELAT R, P279
[6]   Effects of ionizing radiation on the mechanical properties of human bone [J].
Currey, JD ;
Foreman, J ;
Laketic, I ;
Mitchell, J ;
Pegg, DE ;
Reilly, GC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (01) :111-117
[7]  
Delloye C, 1991, Acta Orthop Belg, V57 Suppl 2, P27
[9]   Changes in allograft bone irradiated at different temperatures [J].
Hamer, AJ ;
Stockley, I ;
Elson, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (02) :342-344
[10]   Biomechanical properties of cortical allograft bone using a new method of bone strength measurement - A comparison of fresh, fresh-frozen and irradiated bone [J].
Hamer, AJ ;
Strachan, JR ;
Black, MM ;
Ibbotson, CJ ;
Stockley, I ;
Elson, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (03) :363-368