Microtubule sensors and sensor array based on polyaniline synthesized in the presence of poly(styrene sulfonate)

被引:94
作者
Kanungo, M [1 ]
Kumar, A [1 ]
Contractor, AQ [1 ]
机构
[1] Indian Inst Technol, Dept Chem, Bombay 76, Maharashtra, India
关键词
D O I
10.1021/ac034537h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microtubule sensors for glucose, urea, and triglyceride were fabricated based on poly(styrene sulfonate)-polyaniline (PSS-PANI) composites synthesized within the pores of track-etched polycarbonate membranes. The synthesis of a sufficiently thick and conducting PSS-PANI film at pH 5 provided the advantage of immobilizing enzymes during polymerization. This resulted in the improvement of sensor response for urea and triglyceride by a factor of similar to10(2) with a significant increase in the linear region of response compared to polyaniline-based sensors, where the enzymes were immobilized by physical adsorption after the polymerization. The sensors based on urea and triglyceride were found to have a higher linear range of response, better sensitivity, improved multiple use capability, and faster response time compared to the potentiometric and amperometric sensors based on polyaniline. A microtubule sensor array for glucose, urea, and triglyceride based on PSS-PANI was fabricated by immobilization of three different sets of enzymes on three closely spaced devices and its response was found to be free from cross-interference when a sample containing a mixture of the above analytes was analyzed in a single measurement.
引用
收藏
页码:5673 / 5679
页数:7
相关论文
共 30 条
[1]  
AUSTRIA G, 1991, BER BUNSEN PHYS CHEM, V95, P1381
[2]   Microelectrochemical enzyme transistors [J].
Bartlett, PN ;
Astier, Y .
CHEMICAL COMMUNICATIONS, 2000, (02) :105-112
[3]   Oxidation of beta-nicotinamide adenine dinucleotide (NADH) at poly(aniline)-coated electrodes [J].
Bartlett, PN ;
Birkin, PR ;
Wallace, ENK .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1997, 93 (10) :1951-1960
[4]   Electroactivity, stability and application in an enzyme switch at pH 7 of poly(aniline)-poly(styrenesulfonate) composite films [J].
Bartlett, PN ;
Wang, JH .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1996, 92 (20) :4137-4143
[5]  
Borgstrom B, 1984, LIPASES
[6]   Conductometric uric acid and urea biosensor prepared from electroconductive polyaniline-poly(n-butyl methacrylate) composites [J].
Castillo-Ortega, MM ;
Rodriguez, DE ;
Encinas, JC ;
Plascencia, M ;
Méndez-Velarde, FA ;
Olayo, R .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 85 (1-2) :19-25
[7]   An ion-activated molecular electronic device [J].
Dabke, RB ;
Singh, GD ;
Dhanabalan, A ;
Lal, R ;
Contractor, AQ .
ANALYTICAL CHEMISTRY, 1997, 69 (04) :724-727
[8]   ON THE MECHANISM OF OXIDATIVE POLYMERIZATION OF ANILINE [J].
GOSPODINOVA, N ;
TERLEMEZYAN, L ;
MOKREVA, P ;
KOSSEV, K .
POLYMER, 1993, 34 (11) :2434-2437
[9]   INFLUENCE OF HYDROLYSIS ON THE CHEMICAL POLYMERIZATION OF ANILINE [J].
GOSPODINOVA, N ;
MOKREVA, P ;
TERLEMEZYAN, L .
POLYMER, 1994, 35 (14) :3102-3106
[10]   BIOSENSOR BASED ON CONDUCTING POLYMERS [J].
HOA, DT ;
KUMAR, TNS ;
PUNEKAR, NS ;
SRINIVASA, RS ;
LAL, R ;
CONTRACTOR, AQ .