Quantitative analysis of the microbial metabolome by isotope dilution mass spectrometry using uniformly 13C-labeled cell extracts as internal standards

被引:313
作者
Wu, L [1 ]
Mashego, MR [1 ]
van Dam, JC [1 ]
Proell, AM [1 ]
Vinke, JL [1 ]
Ras, C [1 ]
van Winden, WA [1 ]
van Gulik, WM [1 ]
Heijnen, JJ [1 ]
机构
[1] Delft Univ Technol, Dept Biotechnol, NL-2628 BC Delft, Netherlands
关键词
metabolomics; isotope dilution; LC-MS; intracellular metabolites; C-13; labeling; fed-batch cultivation; Saccharomyces cerevisiae;
D O I
10.1016/j.ab.2004.09.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel method was developed for the quantitative analysis of the microbial metabolome using a mixture of fully uniformly (U) C-13-labeled metabolites as internal standard (IS) in the metabolite extraction procedure the subsequent liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis. This mixture of fully U C-13-labeled metabolites was extracted from biomass of Saccharomyces cerevisiae cultivated in a fed-batch fermentation on fully U C-13-labeled substrates. The obtained labeled cell extract contained, in principle, the whole yeast metabolome, allowing the quantification of any intracellular metabolite of interest in S. cerevisiae. We have applied the labeled cell extract as IS in the analysis of glycolytic and tricarboxylic acid (TCA) cycle intermediates in S. cerevisiae sampled in both steady-state and transient conditions following a glucose pulse. The use of labeled IS effectively reduced errors due to variations occurring in the analysis and sample processing. As a result, the linearity of calibration lines and the precision of measurements were significantly improved. Coextraction of the labeled cell extract with the samples also eliminates the need to perform elaborate recovery checks for each metabolite to be analyzed. In conclusion, the method presented leads to less workload, more robustness, and a higher precision in metabolome analysis. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:164 / 171
页数:8
相关论文
共 27 条
[21]  
Rizzi M, 1997, BIOTECHNOL BIOENG, V55, P592
[22]   Internal standard signal suppression by co-eluting analyte in isotope dilution LC-ESI-MS [J].
Sojo, LE ;
Lum, G ;
Chee, P .
ANALYST, 2003, 128 (01) :51-54
[23]  
Theobald U, 1997, BIOTECHNOL BIOENG, V55, P305, DOI 10.1002/(SICI)1097-0290(19970720)55:2<305::AID-BIT8>3.0.CO
[24]  
2-M
[25]   Effect of slow growth on metabolism of Escherichia coli, as revealed by global metabolite pool ("Metabolome") analysis [J].
Tweeddale, H ;
Notley-McRobb, L ;
Ferenci, T .
JOURNAL OF BACTERIOLOGY, 1998, 180 (19) :5109-5116
[26]   Analysis of glycolytic intermediates in Saccharomyces cerevisiae using anion exchange chromatography and electrospray ionization with tandem mass spectrometric detection [J].
van Dam, JC ;
Eman, MR ;
Frank, J ;
Lange, HC ;
van Dedem, GWK ;
Heijnen, SJ .
ANALYTICA CHIMICA ACTA, 2002, 460 (02) :209-218
[27]   EFFECT OF BENZOIC-ACID ON METABOLIC FLUXES IN YEASTS - A CONTINUOUS-CULTURE STUDY ON THE REGULATION OF RESPIRATION AND ALCOHOLIC FERMENTATION [J].
VERDUYN, C ;
POSTMA, E ;
SCHEFFERS, WA ;
VANDIJKEN, JP .
YEAST, 1992, 8 (07) :501-517