摘要
Usually analysis of low molecular-mass carboxylic acids was performed by anion-exchange or ion-exclusion chromatographic methods. Reversed-phase liquid chromatography (RPLC) was evaluated in this work as an alternative method for the analysis of low molecular-mass aliphatic mono- and di-carboxylic acids (formic, acetic, propionic, butyric, valeric, caproic, succinic, glutaric and adipic) in aqueous media. The separation of the nine organic acids was optimised in 21 min on a high-density C-18 column with an elution gradient made up of HClO4 aqueous solution 10(-3) mol L-1 and acetonitrile. For the quantitation, external standard and standard addition methods were compared. Both methods gave similar results, so the most convenient method, external standard, was chosen for acids quantitation. Then the method had been validated and applied to the semi-quantitative analysis of formic and acetic acids and to the quantitative analysis of the others compounds in industrial reaction mixtures with concentrations ranging from 20 to 570ppm. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:49 / 56
页数:8
相关论文
共 27 条
[21]   SEPARATION OF ALIPHATIC CARBOXYLIC-ACIDS BY ION-EXCLUSION CHROMATOGRAPHY USING A WEAK-ACID ELUENT [J].
TANAKA, K ;
FRITZ, JS .
JOURNAL OF CHROMATOGRAPHY, 1986, 361 :151-160
[22]  
VIAL A, 2001, ENCY CHROMATOGRAPHY, P696
[23]   Taking into account both preparation and injection in high-performance liquid chromatography linearity studies [J].
Vial, J ;
Jardy, A .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2000, 38 (05) :189-194
[24]   What is the best means of estimating the detection and quantification limits of a chromatographic method? [J].
Vial, J ;
Le Mapihan, K ;
Jardy, A .
CHROMATOGRAPHIA, 2003, 57 (Suppl 1) :S303-S306
[25]   Interlaboratory studies: the best way to estimate the characteristics of dispersion of an HPLC method and a powerful tool for analytical transfers [J].
Vial, J ;
Jardy, A .
CHROMATOGRAPHIA, 2001, 53 (Suppl 1) :S141-S148
[26]  
VIAL J, 2001, SPECTRA ANAL, V223, P13
[27]  
Wang T., 2001, ENCY CHROMATOGRAPHY, P691