Theoretical accuracy of model-based shape matching for measuring natural knee kinematics with single-plane fluoroscopy

被引:119
作者
Fregly, BJ [1 ]
Rahman, HA
Banks, SA
机构
[1] Univ Florida, Dept Mech & Aerosp Engn, Gainesville, FL 32611 USA
[2] Univ Florida, Dept Biomed Engn, Gainesville, FL 32611 USA
[3] Univ Florida, Dept Orthopaed & Rehabil, Gainesville, FL 32611 USA
[4] Biomot Fdn, W Palm Beach, FL 33480 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2005年 / 127卷 / 04期
关键词
D O I
10.1115/1.1933949
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Quantification of knee motion under dynamic, in vivo loaded conditions is necessary to understand how knee kinematics influence joint injury, disease, and rehabilitation. Though recent studies have measured three-dimensional knee kinematics by matching geometric bone models to single-plane fluoroscopic images, factors limiting the accuracy of this approach have not been thoroughly investigated. This study used a three-step computational approach to evaluate theoretical accuracy limitations due to the shape matching process alone. First, cortical bone models of the femur tibia/fibula, and patella were created from CT data. Next, synthetic (i.e., computer generated) fluoroscopic images were created by ray tracing the bone models in known poses. Finally, an automated matching algorithm utilizing edge detection methods was developed to align flat-shaded bone models to the synthetic images. Accuracy of the recovered pose parameters was assessed in terms of measurement bias and precision. Under these ideal conditions where other sources of error were eliminated, tibiofemoral poses were within 2 mm for sagittal plane translations and 1.5 deg for all rotations while patellofemoral poses were within 2 mm and 3 deg. However statistically significant bias was found in most relative pose parameters. Bias disappeared and precision improved by a factor of two when the synthetic images were regenerated using flat shading (i.e., sharp bone edges) instead of ray tracing (i.e., attenuated bone edges). Analysis of absolute pose parameter errors revealed that the automated matching algorithm systematically pushed the flat-shaded bone models too far into the image plane to match the attenuated edges of the synthetic ray-traced images. These results suggest that biased edge detection is the primary factor limiting the theoretical accuracy of this single-plane shape matching procedure.
引用
收藏
页码:692 / 699
页数:8
相关论文
共 24 条
[1]
Correcting for deformation in skin-based marker systems [J].
Alexander, EJ ;
Andriacchi, TP .
JOURNAL OF BIOMECHANICS, 2001, 34 (03) :355-361
[2]
A method to estimate in vivo dynamic articular surface interaction [J].
Anderst, WJ ;
Tashman, S .
JOURNAL OF BIOMECHANICS, 2003, 36 (09) :1291-1299
[3]
A Point Cluster Method for In Vivo Motion Analysis: Applied to a Study of Knee Kinematics [J].
Andriacchi, TP ;
Alexander, EJ ;
Toney, MK ;
Dyrby, C .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (06) :743-749
[4]
In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties [J].
Banks, SA ;
Markovich, GD ;
Hodge, WA .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :297-304
[5]
Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy [J].
Banks, SA ;
Hodge, WA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) :638-649
[6]
Surface-marker cluster design criteria for 3-D bone movement reconstruction [J].
Cappozzo, A ;
Cappello, A ;
DellaCroce, U ;
Pensalfini, F .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (12) :1165-1174
[7]
3-DIMENSIONAL ANALYSIS OF HUMAN WALKING - EXPERIMENTAL METHODS AND ASSOCIATED ARTIFACTS [J].
CAPPOZZO, A .
HUMAN MOVEMENT SCIENCE, 1991, 10 (05) :589-602
[8]
*CDCP, 2003, TARG ARTHR NAT LEAD
[9]
Computational wear prediction of a total knee replacement from in vivo kinematics [J].
Fregly, BJ ;
Sawyer, WG ;
Harman, MK ;
Banks, SA .
JOURNAL OF BIOMECHANICS, 2005, 38 (02) :305-314
[10]
A comparison of lower-extremity skeletal kinematics measured using skin- and pin-mounted markers [J].
Fuller, J ;
Liu, LJ ;
Murphy, MC ;
Mann, RW .
HUMAN MOVEMENT SCIENCE, 1997, 16 (2-3) :219-242