Three-dimensional analytical magnetic resonance Imaging phantom in the Fourier domain

被引:37
作者
Koay, Cheng Guan [1 ]
Sarls, Joelle E. [1 ]
Ozarslan, Evren [1 ]
机构
[1] NICHHD, NIH, Bethesda, MD 20892 USA
关键词
3D analytical MRI phantom; 3D Fourier domain phantom; Fourier transform of an ellipsoid; MRI phantom; Shepp-Logan;
D O I
10.1002/mrm.21292
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
This work presents a basic framework for constructing a 3D analytical MRI phantom in the Fourier domain. In the image domain the phantom is modeled after the work of Kak and Roberts on a 3D version of the famous Shepp-Logan head phantom. This phantom consists of several ellipsoids of different sizes, orientations, locations, and signal intensities (or gray levels). It will be shown that the k-space signal derived from the phantom can be analytically expressed. As a consequence, it enables one to bypass the need for interpolation in the Fourier domain when testing image-reconstruction algorithms. More importantly, the proposed framework can serve as a benchmark for contrasting and comparing different image-reconstruction techniques in 3D MRI with a non-Cartesian k-space trajectory. The proposed framework can also be adapted for 3D MRI simulation studies in which the MRI parameters of interest may be introduced to the signal intensity from the ellipsoid.
引用
收藏
页码:430 / 436
页数:7
相关论文
共 33 条
[1]
Arfken G. B., 2001, MATH METHODS PHYS, P796
[2]
Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory [J].
Barger, AV ;
Block, WF ;
Toropov, Y ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) :297-305
[3]
MR DIFFUSION TENSOR SPECTROSCOPY AND IMAGING [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
BIOPHYSICAL JOURNAL, 1994, 66 (01) :259-267
[4]
Inferring microstructural features and the physiological state of tissues from diffusion-weighted images [J].
Basser, PJ .
NMR IN BIOMEDICINE, 1995, 8 (7-8) :333-344
[5]
BRACEWELL RN, 1986, FOURIER TRANSFORM IT, P253
[6]
B-11 IMAGING WITH A 3-DIMENSIONAL RECONSTRUCTION METHOD [J].
GLOVER, GH ;
PAULY, JM ;
BRADSHAW, KM .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (01) :47-52
[7]
Design and analysis of a practical 3D cones trajectory [J].
Gurney, PT ;
Hargreaves, BA ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) :575-582
[8]
FAST 3-DIMENSIONAL MAGNETIC-RESONANCE-IMAGING [J].
IRARRAZABAL, P ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :656-662
[9]
Flow properties of fast three-dimensional sequences for MR angiography [J].
Irarrázaval, P ;
Santos, JM ;
Guarini, M ;
Nishimura, D .
MAGNETIC RESONANCE IMAGING, 1999, 17 (10) :1469-1479
[10]
SELECTION OF A CONVOLUTION FUNCTION FOR FOURIER INVERSION USING GRIDDING [J].
JACKSON, JI ;
MEYER, CH ;
NISHIMURA, DG ;
MACOVSKI, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) :473-478