Corneal curvature and central corneal thickness in eyes with pseudoexfoliation syndrome

被引:34
作者
Hepsen, Ibrahim E.
Yagci, Ramazan
Keskin, Urgcan
机构
[1] Fatih Univ Hosp, Ctr Eye, TR-06510 Ankara, Turkey
[2] Fatih Univ, Sch Med, Dept Ophthalmol, Ankara, Turkey
来源
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE | 2007年 / 42卷 / 05期
关键词
central corneal thickness; corneal curvature; Scheimpflug corneal topography; pseudoexfoliation syndrome;
D O I
10.3129/i07-145
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Previous studies have reported different central corneal thickness (CCT) values in eyes with pseudoexfoliation syndrome (PXS).There has been no report about corneal curvature (CC) in PXS eyes. The aim of this study was to investigate the CCT together with the CC in PXS eyes with and without glaucoma. Methods: The CC (simulated keratometry 1 [SimK 1], SimK2, and mean K) and CCT were prospectively studied by rotating a Scheimpflug camera in 72 PXS eyes and comparing them with 65 normal eyes. Results: In all PXS eyes, the mean K was significantly steeper than in control eyes (44.1 [SD 1.5] diopters (D) vs. 43.2 [SD 2.0] D, p = 0.04).When PXS eyes were subcategorized, the mean K was significantly steeper in both normotensive PXS eyes (44.6 [SD 1.6] D) and pseudoexfoliation glaucoma (PEXG) eyes (44.0 [SD 1.2] D) than normal eyes (43.2 [SD 2.0] D) (p = 0.001 and 0.02, respectively). In all PXS eyes, the mean CCT (546.4 [SD 39.6] pm) was not significantly different than the control eyes (542.9 [SD 32.2] Itm) (p = 0.56). When PXS eyes were subcategorized, however, the CCT was significantly thinner in normotensive PXS eyes and significantly thicker in PEXG eyes.
引用
收藏
页码:677 / 680
页数:4
相关论文
共 19 条
[1]   Central corneal thickness of Caucasians, Chinese, Hispanics, Filipinos, African Americans, and Japanese in a glaucoma clinic [J].
Aghaian, E ;
Choe, JE ;
Lin, S ;
Stamper, RL .
OPHTHALMOLOGY, 2004, 111 (12) :2211-2219
[2]   Central corneal thickness determined with optical coherence tomography in various types of glaucoma [J].
Bechmann, M ;
Thiel, MJ ;
Roesen, B ;
Ullrich, S ;
Ulbig, MW ;
Ludwig, K .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2000, 84 (11) :1233-1237
[3]  
Copt RP, 1999, ARCH OPHTHALMOL-CHIC, V117, P14
[4]   Central corneal mechanical sensitivity in pseudoexfoliation syndrome [J].
Detorakis, ET ;
Koukoula, S ;
Chrisohoou, F ;
Konstas, AG ;
Kozobolis, VP .
CORNEA, 2005, 24 (06) :688-691
[5]  
EHLERS N, 1975, ACTA OPHTHALMOL, V53, P34
[6]   Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer [J].
Gunvant, P ;
Baskaran, M ;
Vijaya, L ;
Joseph, IS ;
Watkins, RJ ;
Nallapothula, M ;
Broadway, DC ;
O'Leary, DJ .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (04) :518-522
[7]   Increased corneal thickness in patients with ocular hypertension [J].
Herman, DC ;
Hodge, DO ;
Bourne, WM .
ARCHIVES OF OPHTHALMOLOGY, 2001, 119 (03) :334-336
[8]   Central corneal thickness in normal, glaucomatous, and ocular hypertensive eyes [J].
Herndon, LW ;
Choudhri, SA ;
Cox, T ;
Damji, KF ;
Shields, MB ;
Allingham, RR .
ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (09) :1137-1141
[9]   Morphological study of corneal endothelium and corneal thickness in pseudoexfoliation syndrome [J].
Inoue, K ;
Okugawa, K ;
Oshika, T ;
Amano, S .
JAPANESE JOURNAL OF OPHTHALMOLOGY, 2003, 47 (03) :235-239
[10]   CORNEAL CURVATURE IN APPLANATION TONOMETRY [J].
MARK, HH .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1973, 76 (02) :223-224