Human observer detection experiments with mammograms and power-law noise

被引:448
作者
Burgess, AE [1 ]
Jacobson, FL [1 ]
Judy, PF [1 ]
机构
[1] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Radiol, Boston, MA 02115 USA
关键词
anatomical backgrounds; contrast-detail diagrams; image quality; mammography; observer models;
D O I
10.1118/1.1355308
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We determined contrast thresholds for lesion detection as a function of lesion size in both mammograms and filtered noise backgrounds with the same average power spectrum, P(f) = Blf(3). Experiments were done using hybrid images with digital images of tumors added to digitized normal backgrounds, displayed on a monochrome monitor. Four tumors were extracted from digitized specimen radiographs. The lesion sizes were varied by digital rescaling to cover the range from 0.5 to 16 mm. Amplitudes were varied to determine the value required for 92% correct detection in two-alternative forced-choice (2AFC) and 90% for search experiments. Three observers participated, two physicists and a radiologist. The 2AFC mammographic results demonstrated a novel contrast-detail (CD) diagram with threshold amplitudes that increased steadily (with slope of 0.3) with increasing size for lesions larger than 1 mm. The slopes for prewhitening model observers were about 0.4. Human efficiency relative to these models was as high as 90%. The CD diagram slopes for the 2AFC experiments with filtered noise were 0.44 for humans and 0.5 for models. Human efficiency relative to the ideal observer was about 40%. The difference in efficiencies for the two types of backgrounds indicates that breast structure cannot be considered to be pure random noise for 2AFC experiments. Instead, 2AFC human detection with mammographic backgrounds is limited by a combination of noise and deterministic masking effects. The search experiments also gave thresholds that increased with lesion size. However, there was no difference in human results for mammographic and filtered noise backgrounds, suggesting that breast structure can be considered to be pure random noise for this task. Our conclusion is that, in spite of the fact that mammographic backgrounds have nonstationary statistics, models based on statistical decision theory can still be applied successfully to estimate human performance. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:419 / 437
页数:19
相关论文
共 72 条
  • [1] ABBEY C, 1998, THESIS U ARIZONA
  • [2] Abbey C. K., 2000, HDB MED IMAGING, V1, P629
  • [3] Adelson E.H., 1991, COMPUTATIONAL MODELS
  • [4] [Anonymous], 1988, SCI FRACTAL IMAGES
  • [5] Barrett H. H., 1986, Proceedings of the SPIE - The International Society for Optical Engineering, V626, P231, DOI 10.1117/12.975398
  • [6] MODEL OBSERVERS FOR ASSESSMENT OF IMAGE QUALITY
    BARRETT, HH
    YAO, J
    ROLLAND, JP
    MYERS, KJ
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1993, 90 (21) : 9758 - 9765
  • [7] Stabilized estimates of Hotelling-observer detection performance in patient-structured noise
    Barrett, HH
    Abbey, CK
    Gallas, B
    Eckstein, M
    [J]. IMAGE PERCEPTION: MEDICAL IMAGING 1998, 1998, 3340 : 27 - 43
  • [8] BARTEN PGJ, 1990, SID S, V31, P239
  • [9] Bendat JS., 2011, RANDOM DATA ANAL MEA
  • [10] Estimation of the noisy component of anatomical backgrounds
    Bochud, FO
    Valley, JF
    Verdun, FR
    Hessler, C
    Schnyder, P
    [J]. MEDICAL PHYSICS, 1999, 26 (07) : 1365 - 1370