Estimation of the noisy component of anatomical backgrounds

被引:151
作者
Bochud, FO
Valley, JF
Verdun, FR
Hessler, C
Schnyder, P
机构
[1] Inst Radiophys Appl, CH-1007 Lausanne, Switzerland
[2] CHU Vaudois, Serv Radiodiagnost & Radiol Intervent, CH-1011 Lausanne, Switzerland
关键词
detection experiment; observer model; image quality; image noise; anatomical background;
D O I
10.1118/1.598632
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The knowledge of the relationship that links radiation dose and image quality is a prerequisite to any optimization of medical diagnostic radiology. Image quality depends, on the one hand, on the physical parameters such as contrast, resolution, and noise, and on the other hand, on characteristics of the observer that assesses the image. While the role of contrast and resolution is precisely defined and recognized, the influence of image noise is not yet fully understood. Its measurement is often based on imaging uniform test objects, even though real images contain anatomical backgrounds whose statistical nature is much different from test objects used to assess system noise. The goal of this study was to demonstrate the importance of variations in background anatomy by quantifying its effect on a series of detection tasks. Several types of mammographic backgrounds and signals were examined by psychophysical experiments in a two-alternative forced-choice detection task. According to hypotheses concerning the strategy used by the human observers, their signal to noise ratio was determined. This variable was also computed for a mathematical model based on the statistical decision theory. By comparing theoretical model and experimental results, the way that anatomical structure is perceived has been analyzed. Experiments showed that the observer's behavior was highly dependent upon both system noise and the anatomical background. The anatomy partly acts as a signal recognizable as such and partly as a pure noise that disturbs the detection process. This dual nature of the anatomy is quantified. It is shown that its effect varies according to its amplitude and the profile of the object being detected. The importance of the noisy part of the anatomy is, in some situations, much greater than the system noise. Hence, reducing the system noise by increasing the dose will not improve task performance. This observation indicates that the tradeoff between dose and image quality might be optimized by accepting a higher system noise. This could lead to a better resolution, more contrast, or less dose. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)01807-6].
引用
收藏
页码:1365 / 1370
页数:6
相关论文
共 22 条
[1]  
BOCHUD FO, 1995, P SOC PHOTO-OPT INS, V2436, P156, DOI 10.1117/12.206845
[2]   The importance of anatomical noise in mammography [J].
Bochud, FO ;
Verdun, FR ;
Valley, JF ;
Hessler, C ;
Moeckli, R .
IMAGE PERCEPTION: MEDICAL IMAGING 1997, 1997, 3036 :74-80
[3]  
BOCHUD FO, 1999, Z MED PHYS, V9, P48
[4]  
BOCHUD FO, 1997, THESIS U LAUSANNE SW
[5]   VISUAL SIGNAL-DETECTION .1. ABILITY TO USE PHASE INFORMATION [J].
BURGESS, A ;
GHANDEHARIAN, H .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (08) :900-905
[6]   EFFICIENCY OF HUMAN VISUAL SIGNAL DISCRIMINATION [J].
BURGESS, AE ;
WAGNER, RF ;
JENNINGS, RJ ;
BARLOW, HB .
SCIENCE, 1981, 214 (4516) :93-94
[7]  
BURGESS AE, 1995, P SOC PHOTO-OPT INS, V2436, P2, DOI 10.1117/12.206837
[8]   COMPARISON OF RECEIVER OPERATING CHARACTERISTIC AND FORCED-CHOICE OBSERVER PERFORMANCE-MEASUREMENT METHODS [J].
BURGESS, AE .
MEDICAL PHYSICS, 1995, 22 (05) :643-655
[9]   VISUAL PROCESSING OF SIMPLE 2-DIMENSIONAL SINE-WAVE LUMINANCE GRATINGS [J].
CARLSON, CR ;
COHEN, RW ;
GOROG, I .
VISION RESEARCH, 1977, 17 (03) :351-358
[10]   Visual signal detection in structured backgrounds .1. Effect of number of possible spatial locations and signal contrast [J].
Eckstein, MP ;
Whiting, JS .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1996, 13 (09) :1777-1787