Zernike phase contrast cryo-electron tomography

被引:48
作者
Danev, Radostin [1 ]
Kanamaru, Shuji [2 ]
Marko, Michael [3 ]
Nagayama, Kuniaki [1 ]
机构
[1] Natl Inst Nat Sci, Okazaki Inst Integrat Biosci, Okazaki, Aichi 4448787, Japan
[2] Tokyo Inst Technol, Yokohama, Kanagawa 227, Japan
[3] Wadsworth Ctr, Albany, NY USA
基金
日本科学技术振兴机构;
关键词
Cryotomography; Cryomicroscopy; Phase plate; Phase contrast; Gibbs phenomenon; Bacteriophage; TRANSMISSION ELECTRON-MICROSCOPY; PLATE; TEM;
D O I
10.1016/j.jsb.2010.03.013
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Cryo-tomography in the electron microscope is unique in its ability to provide high-resolution, three-dimensional structural information about cells, organelles and macromolecules in a nearly native, frozen-hydrated state. However, the phase-contrast imaging method used in conventional cryo-electron tomography fails to faithfully represent the full range of structural features in such specimens. Only certain features are recorded with adequate contrast, and overall contrast is low. The recently developed Zernike phase contrast method has the potential to solve this problem, and here we apply it for the first time to cryo-electron tomography. The new method has uniform transfer characteristics for a wide range of spatial frequencies, leading to improved overall signal-to-noise ratio and raising the prospects of higher resolution and quantitative representation of specimen densities in the reconstructed tomograms. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:174 / 181
页数:8
相关论文
共 18 条
[1]   Improved specimen reconstruction by Hilbert phase contrast tomography [J].
Barton, Bastian ;
Joos, Friederike ;
Schroeder, Rasmus R. .
JOURNAL OF STRUCTURAL BIOLOGY, 2008, 164 (02) :210-220
[2]   From proteomic inventory to architecture [J].
Baumeister, W .
FEBS LETTERS, 2005, 579 (04) :933-937
[3]   Design of a microfabricated, two-electrode phase-contrast element suitable for electron microscopy [J].
Cambie, Rossana ;
Downing, Kenneth H. ;
Typke, Dieter ;
Glaeser, Robert M. ;
Jin, Jian .
ULTRAMICROSCOPY, 2007, 107 (4-5) :329-339
[4]   Transmission electron microscopy with Zernike phase plate [J].
Danev, R ;
Nagayama, K .
ULTRAMICROSCOPY, 2001, 88 (04) :243-252
[5]   Single particle analysis based on Zernike phase contrast transmission electron microscopy [J].
Danev, Radostin ;
Nagayama, Kuniaki .
JOURNAL OF STRUCTURAL BIOLOGY, 2008, 161 (02) :211-218
[6]  
Danev Radostin, 2006, Biophysics (Nagoya-shi), V2, P35, DOI 10.2142/biophysics.2.35
[7]   Practical factors affecting the performance of a thin-film phase plate for transmission electron microscopy [J].
Danev, Radostin ;
Glaeser, Robert M. ;
Nagayama, Kuniaki .
ULTRAMICROSCOPY, 2009, 109 (04) :312-325
[8]  
Frank J., 2006, Electron Tomography: Methods for Three-Dimensional Visualization of Structures in the Cell
[9]   Tuning of the Zernike phase-plate for visualization of detailed ultrastructure in complex biological specimens [J].
Fukuda, Yoshiyuki ;
Fukazawa, Yugo ;
Danev, Radostin ;
Shigemoto, Ryuichi ;
Nagayama, Kuniaki .
JOURNAL OF STRUCTURAL BIOLOGY, 2009, 168 (03) :476-484
[10]   A simple large-scale synthesis of nearly monodisperse gold and silver nanoparticles with adjustable sizes and with exchangeable surfactants [J].
Hiramatsu, H ;
Osterloh, FE .
CHEMISTRY OF MATERIALS, 2004, 16 (13) :2509-2511