Transmission electron microscopy with Zernike phase plate

被引:218
作者
Danev, R [1 ]
Nagayama, K [1 ]
机构
[1] Okazaki Natl Res Inst, Natl Inst Physiol Sci, Okazaki, Aichi 4448585, Japan
关键词
phase plate; phase contrast; contrast transfer function; transmission electron microscope;
D O I
10.1016/S0304-3991(01)00088-2
中图分类号
TH742 [显微镜];
学科分类号
摘要
The possibility of implementing a Zernike phase plate in a transmission electron microscope is investigated both theoretically and experimentally. The phase-retarding plate in the form of thin film with a hole in the center is positioned in the back-focal plane of the objective lens. The experiments show that the phase plate functions as predicted, producing a cosine-type phase contrast transfer function. Images of negatively stained horse spleen ferritin were highly improved in the contrast and the image-modulation, compared to those acquired without the phase plate. Charging and related difficulties were encountered during the phase plate experiments. In order to make the technique user-friendly a number of improvements have to be made, and are discussed in terms of the current level of technology and instrumentation. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:243 / 252
页数:10
相关论文
共 22 条
[1]   Elastic and inelastic scattering cross-sections of amorphous layers of carbon and vitrified ice [J].
Angert, I ;
Burmester, C ;
Dinges, C ;
Rose, H ;
Schroder, RR .
ULTRAMICROSCOPY, 1996, 63 (3-4) :181-192
[2]  
[Anonymous], 1971, ELECT MICROSCOPY MAT
[3]   INFLUENCE OF A SCATTERING PHASE PLATE ON AN ELECTRON-MICROSCOPIC PICTURE [J].
BADDE, HG ;
REIMER, L .
ZEITSCHRIFT FUR NATURFORSCHUNG PART A-ASTROPHYSIK PHYSIK UND PHYSIKALISCHE CHEMIE, 1970, A 25 (05) :760-&
[4]  
BIGELOW W, 1994, VACUUM METHODS ELECT, V15
[5]   PHASE RETRIEVAL THROUGH FOCUS VARIATION FOR ULTRA-RESOLUTION IN FIELD-EMISSION TRANSMISSION ELECTRON-MICROSCOPY [J].
COENE, W ;
JANSSEN, G ;
DEBEECK, MO ;
VANDYCK, D .
PHYSICAL REVIEW LETTERS, 1992, 69 (26) :3743-3746
[6]   Complex observation in electron microscopy. II. Direct visualization of phases and amplitudes of exit wave functions [J].
Danev, R ;
Nagayama, K .
JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 2001, 70 (03) :696-702
[7]  
DANOV K, UNPUB ULTRAMICROSCOP
[8]  
FAGET J, 1962, P 5 INT C EL MICR NE, pA7
[9]  
JOHNSON HM, 1973, PRINCIPLES TECHNIQUE, V3, P153
[10]   EXPERIMENT ON THE ELECTRON PHASE MICROSCOPE [J].
KANAYA, K ;
KAWAKATSU, H ;
ITO, K ;
YOTSUMOTO, H .
JOURNAL OF APPLIED PHYSICS, 1958, 29 (07) :1046-1049