Validation of a hand-held lactate device in determination of blood lactate in critically injured patients

被引:48
作者
Slomovitz, BM
Lavery, RF
Tortella, BJ
Siegel, JH
Bachl, BL
Ciccone, A
机构
[1] Univ Hosp, Dept Surg, Newark, NJ 07103 USA
[2] Univ Hosp, Dept Anat Cell Biol & Injury Sci, Newark, NJ 07103 USA
[3] Univ Hosp, New Jersey Trauma & EMS Res Ctr, Newark, NJ 07103 USA
[4] Univ Med & Dent New Jersey, New Jersey Med Sch, Newark, NJ 07103 USA
[5] Emergency Med Associates, Morristown, NJ USA
关键词
lactate; point of care testing; critical care; trauma; shock; resuscitation; whole blood analysis; clinical chemistry; wounds and injuries; hypovolemia;
D O I
10.1097/00003246-199809000-00019
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: Admission blood lactate is an accurate predictor of injury severity and mortality in trauma patients. The purpose of this study was to evaluate a portable lactate analyzer in a clinical setting by patient care staff. Design: A prospective, single operator control solution and patient sample study, using two test devices and a reference device. Setting: An urban Level I trauma center. Patients: A convenience sample of 47 trauma patients. Interventions: Intra-assay precision was demonstrated by performance of consecutive analyses of two lactate control solutions (high and low lactate control concentrations) by medical students and physicians. Split sample, simultaneous testing of the portable lactate analyzer was then performed on 66 whole blood specimens from a convenience sample of 47 trauma patients admitted to an urban Level 1 trauma center over 4 mos. Samples were tested simultaneously tested on two portable lactate analyzers and a reference instrument. Measurements and Main Results: Acceptable intra-assay precision was achieved. Regression analysis for two test instruments demonstrated a slope of 0.920, an intercept of 0.323, an r(2) of .982, and an SEM Of 0.496. Regression analysis for test instrument "A" vs. the reference instrument showed a slope of 0.861, an intercept of 0.209, an r(2) of .977, and an SEM Of 0.598. Regression analysis for test instrument "B" vs. the reference instrument demonstrated a slope of 0.929, an intercept of -0.095, an r(2) of .983, and an SEM Of 0.506. Conclusions: Good correlation with a low SEM was obtained over a wide range of clinically relevant lactate values. Use of point of care lactate analysis will decrease analytic time, making an important diagnostic parameter immediately available in the critical care setting. (Crit Care Med 1998; 26:1523-1528).
引用
收藏
页码:1523 / 1528
页数:6
相关论文
共 33 条
[1]   LACTATE CLEARANCE AND SURVIVAL FOLLOWING INJURY [J].
ABRAMSON, D ;
SCALEA, TM ;
HITCHCOCK, R ;
TROOSKIN, SZ ;
HENRY, SM ;
GREENSPAN, J .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1993, 35 (04) :584-589
[2]   THE USE AND CLINICAL IMPORTANCE OF A SUBSTRATE-SPECIFIC ELECTRODE FOR RAPID-DETERMINATION OF BLOOD LACTATE CONCENTRATIONS [J].
ADUEN, J ;
BERNSTEIN, WK ;
KHASTGIR, T ;
MILLER, JA ;
KERZNER, R ;
BHATIANI, A ;
LUSTGARTEN, J ;
BASSIN, AS ;
DAVISON, L ;
CHERNOW, B .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 272 (21) :1678-1685
[3]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[4]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[5]  
*BOEHR MANNH CORP, 1995, ACC PROD INF
[6]  
*BOEHR MANNH CORP, 1995, LACT TEST STRIPS PRO
[7]   EXCESS LACTATE - INDEX OF REVERSIBILITY OF SHOCK IN HUMAN PATIENTS [J].
BRODER, G ;
WEIL, MH .
SCIENCE, 1964, 143 (361) :1457-&
[8]  
FALK JL, 1985, ACUTE CARE, V11, P212
[9]  
FUHRMAN SA, 1995, ARCH PATHOL LAB MED, V119, P939
[10]  
GAGLIO G, 1886, ARCH ANAT PHYSL ABT, V10, P400