Numerical simulation of flow in mechanical heart valves: Grid resolution and the assumption of flow symmetry

被引:59
作者
Ge, L
Jones, SC
Sotiropoulos, F [1 ]
Healy, TM
Yoganathan, AP
机构
[1] Georgia Inst Technol, Sch Civil & Environm Engn, Atlanta, GA 30332 USA
[2] Exxon Mobil Res & Engn, Fairfax, VA 22037 USA
[3] Georgia Inst Technol, Walter H Coulter Sch Biomed Engn, Atlanta, GA 30332 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2003年 / 125卷 / 05期
关键词
D O I
10.1115/1.1614817
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A numerical method is developed for simulating unsteady, 3-D, laminar flow through a bileaflet mechanical heart valve with the leaflets fixed. The method employs a dual-time-stepping artificial-compressibility approach together with overset (Chimera) grids and is second-order accurate in space and time. Calculations are carried out for the full 3-D valve geometry under steady inflow conditions on meshes with a total number of nodes ranging from 4 x 10(5) to 1.6 x 10(6). The computed results show that downstream of the leaflets the flow is dominated by two pairs of counter-rotating vortices, which originate on either side of the central orifice in the aortic sinus and rotate such that the common flow of each pair is directed away from the aortic wall. These vortices intensify with Reynolds number and at a Reynolds number of approximately 1200 their complex interaction leads to the onset of unsteady flow and the break of symmetry with respect to both geometric planes of symmetry. Our results show the highly 3-D structure of the flow; question the validity, of computationally expedient assumptions of flow symmetry; and demonstrate the need for highly resolved, fully 3-D simulations if computational fluid dynamics is to accurately predict the flow in prosthetic mechanical heart valves.
引用
收藏
页码:709 / 718
页数:10
相关论文
共 26 条
[1]   Numerical simulation of mechanical mitral heart valve closure [J].
Aluri, S ;
Chandran, KB .
ANNALS OF BIOMEDICAL ENGINEERING, 2001, 29 (08) :665-676
[2]   FLOW INSTABILITY IN A CURVED DUCT OF RECTANGULAR CROSS-SECTION [J].
BELAIDI, A ;
JOHNSON, MW ;
HUMPHREY, JAC .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1992, 114 (04) :585-592
[3]  
DEHART J, 2002, THESIS EINDHOVEN U T
[4]   A dual-pressure boundary condition for use in simulations of bifurcating conduits [J].
Gin, R ;
Straatman, AG ;
Steinman, DA .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (05) :617-619
[5]   IS THE STEADY VISCOUS INCOMPRESSIBLE 2-DIMENSIONAL FLOW OVER A BACKWARD-FACING STEP AT RE=800 STABLE [J].
GRESHO, PM ;
GARTLING, DK ;
TORCZYNSKI, JR ;
CLIFFE, KA ;
WINTERS, KH ;
GARRATT, TJ ;
SPENCE, A ;
GOODRICH, JW .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 1993, 17 (06) :501-541
[6]  
HEALY TH, 2001, THESIS GEORGIA I TEC
[7]   NUMERICAL-SIMULATION OF UNSTEADY LAMINAR-FLOW THROUGH A TILTING DISK HEART-VALVE - PREDICTION OF VORTEX SHEDDING [J].
HUANG, ZJ ;
MERKLE, CL ;
ABDALLAH, S ;
TARBELL, JM .
JOURNAL OF BIOMECHANICS, 1994, 27 (04) :391-402
[8]  
King M. J., 1994, Proceedings of the Institution of Mechanical Engineers, Part H (Journal of Engineering in Medicine), V208, P63, DOI 10.1243/PIME_PROC_1994_208_267_02
[9]   A three-dimensional, time-dependent analysis of flow through a bileaflet mechanical heart valve: Comparison of experimental and numerical results [J].
King, MJ ;
Corden, J ;
David, T ;
Fisher, J .
JOURNAL OF BIOMECHANICS, 1996, 29 (05) :609-618
[10]   Three-dimensional study of the effect of two leaflet opening angles on the time-dependent flow through a bileaflet mechanical heart valve [J].
King, MJ ;
David, T ;
Fisher, J .
MEDICAL ENGINEERING & PHYSICS, 1997, 19 (03) :235-241