Evaluation of a near-infrared spectrometer (NIRO 300) for the detection of intracranial oxygenation changes in the adult head

被引:225
作者
Al-Rawi, PG [1 ]
Smielewski, P [1 ]
Kirkpatrick, PJ [1 ]
机构
[1] Univ Cambridge, Addenbrookes Hosp, Dept Neurosurg, Cambridge CB2 2QQ, England
关键词
carotid endarterectomy; cerebral ischemia; oxygen; spectroscopy; near-infrared;
D O I
10.1161/hs1101.098356
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-The clinical application of intracranial near-infrared spectroscopy in adults has been hampered by concerns over contamination from extracranial tissues. The NIRO 300 (Hamamatsu Photonics) provides continuous online measurements of hemoglobin and cytochrome oxidase concentrations and a calculated tissue oxygen index (TOI). The present study seeks confirmation of the anatomic source of TOI in the adult cranium. Methods-Sixty patients undergoing carotid endarterectomy were studied. The NIRO 300 was incorporated into an established multimodal monitoring system. TOI, oxyhemoglobin, and deoxyhemoglobin changes were assessed and compared with (1) frontal cutaneous laser-Doppler flowmetry and (2) transcranial Doppler measurement of the ipsilateral middle cerebral artery flow velocity. Results-Changes in TOI were seen during cross-clamping of the carotid vessels in 49 patients (mean Delta TOI= -9.4%, SD=7.1). Significant correlation was seen between TOI and flow velocity (r=0.56) but not with laser-Doppler flowmetry (r=0.13). In 31 patients, oxyhemoglobin and deoxyhemoglobin concentrations were recorded, showing significant changes during both external carotid artery and internal carotid artery clamping. A change in TOI was predominantly associated with internal carotid artery clamping (n=41). When TOI changed during external carotid artery clamping (n=8), significant blood pressure changes occurred, or extracranial-to-intracranial anastomosis was evident. In the absence of such variables, the sensitivity of TOI to intracranial and extracranial changes was 87.5% and 0%, respectively, and specificity was 100% and 0%, respectively. Conclusions-The NIRO 300 reflects changes in cerebral tissue oxygenation when TOI is calculated, with a high degree of sensitivity and specificity.
引用
收藏
页码:2492 / 2499
页数:8
相关论文
共 45 条
[1]   Assessment of spatially resolved spectroscopy during cardiopulmonary bypass [J].
Al-Rawi, PG ;
Smielewski, P ;
Hobbiger, H ;
Ghosh, S ;
Kirkpatrick, PJ .
JOURNAL OF BIOMEDICAL OPTICS, 1999, 4 (02) :208-216
[2]   ANATOMICAL STUDIES OF THE CIRCLE OF WILLIS IN NORMAL BRAIN [J].
ALPERS, BJ ;
BERRY, RG ;
PADDISON, RM .
ARCHIVES OF NEUROLOGY AND PSYCHIATRY, 1959, 81 (04) :409-418
[3]   CORRELATION OF CT CEREBRAL VASCULAR TERRITORIES WITH FUNCTION .3. MIDDLE CEREBRAL-ARTERY [J].
BERMAN, SA ;
HAYMAN, LA ;
HINCK, VC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 142 (05) :1035-1040
[4]   Near-infrared spectroscopy -: not useful to monitor cerebral oxygenation after severe brain injury [J].
Büchner, K ;
Meixensberger, J ;
Dings, J ;
Roosen, K .
ZENTRALBLATT FUR NEUROCHIRURGIE, 2000, 61 (02) :69-73
[5]   THE EFFECT OF CHANGES IN CEREBRAL PERFUSION-PRESSURE UPON MIDDLE CEREBRAL-ARTERY BLOOD-FLOW VELOCITY AND JUGULAR BULB VENOUS OXYGEN-SATURATION AFTER SEVERE BRAIN INJURY [J].
CHAN, KH ;
MILLER, JD ;
DEARDEN, NM ;
ANDREWS, PJD ;
MIDGLEY, S .
JOURNAL OF NEUROSURGERY, 1992, 77 (01) :55-61
[6]   SYSTEM FOR LONG-TERM MEASUREMENT OF CEREBRAL BLOOD AND TISSUE OXYGENATION ON NEWBORN-INFANTS BY NEAR-INFRARED TRANS-ILLUMINATION [J].
COPE, M ;
DELPY, DT .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1988, 26 (03) :289-294
[7]   COMPUTER-SUPPORTED MULTIMODAL BED-SIDE MONITORING FOR NEURO INTENSIVE-CARE [J].
CZOSNYKA, M ;
WHITEHOUSE, H ;
SMIELEWSKI, P ;
KIRKPATRICK, P ;
GUAZZO, EP ;
PICKARD, JD .
INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1994, 11 (04) :223-232
[8]   Near-infrared spectroscopy of the adult head: effect of scattering and absorbing obstructions in the cerebrospinal fluid layer on light distribution in the tissue [J].
Dehghani, H ;
Delpy, DT .
APPLIED OPTICS, 2000, 39 (25) :4721-4729
[9]   ESTIMATION OF OPTICAL PATHLENGTH THROUGH TISSUE FROM DIRECT TIME OF FLIGHT MEASUREMENT [J].
DELPY, DT ;
COPE, M ;
VANDERZEE, P ;
ARRIDGE, S ;
WRAY, S ;
WYATT, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (12) :1433-1442
[10]  
DUNCAN A, 1993, P SOC PHOTO-OPT INS, V1888, P248, DOI 10.1117/12.154641