Near-infrared spectroscopy -: not useful to monitor cerebral oxygenation after severe brain injury

被引:49
作者
Büchner, K [1 ]
Meixensberger, J [1 ]
Dings, J [1 ]
Roosen, K [1 ]
机构
[1] Univ Wurzburg, Dept Neurosurg, D-97080 Wurzburg, Germany
来源
ZENTRALBLATT FUR NEUROCHIRURGIE | 2000年 / 61卷 / 02期
关键词
neuromonitoring; brain tissue partial pressure; head injury; subarachnoid hemorrhage;
D O I
10.1055/s-2000-8262
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Since its development more than twenty years ago, non-invasive near-infrared-spectroscopy (NIRS) has been widely used to monitor cerebral oxygenation. Despite of its growing number of users, the diagnostic value of near-infrared spectroscopy still remains unclear, especially in case of acute brain injury and long-term neuromonitoring, necessary during intensive care therapy. To evaluate quality and sensitivity of NIRS measurements compared to invasive ICP-, CPP- and regional brain tissue - pO(2) (p(ti)O-2) monitoring, 31 patients, suffering from severe brain injury due to subarachnoid hemorrhage or severe head injury, were studied. NIRS measurements were only possible in 80% (using the INVOS oximeter) and in 46% (using the CRITIKON monitor), while good data quality was obtained in 100% from ICP, CPP and p(ti)O-2. Major reasons for the failure of NIRS measurements were: (1) a wet chamber between sensor and skin, (2) galea hematoma or (3) subdural air after craniotomy. Different tests were performed to compare the sensitivity of regular oxygen saturation (NIRS) with the sensitivity of invasively determined p(ti)O-2. Only induced hyperoxia (FiO(2)=1.0) revealed a significant correlation between both parameters (r=0.67, p<0.01). Lower or no correlation was found after changing p(a)CO(2) and administration of mannitol. The high failure rate and the limited sensitivity does not make the clinical use of near-infrared spectroscopy suitable as a part of neuromonitoring after acute brain injury at the present time.
引用
收藏
页码:69 / 73
页数:5
相关论文
共 20 条
[1]  
Adelson PD, 1998, ACT NEUR S, V71, P250
[2]  
CLARK LC, 1956, T AM SOC ART INT ORG, V2, P41
[3]   Clinical experience with 118 brain tissue oxygen partial pressure catheter probes [J].
Dings, J ;
Meixensberger, J ;
Jager, A ;
Roosen, K .
NEUROSURGERY, 1998, 43 (05) :1082-1094
[4]   Brain tissue pO(2)-monitoring: Catheter stability and complications [J].
Dings, J ;
Meixensberger, J ;
Roosen, K .
NEUROLOGICAL RESEARCH, 1997, 19 (03) :241-245
[5]  
DUJOVNY M, 1994, NEUROSURGERY, V34, P935
[6]   EARLY DETECTION OF DELAYED TRAUMATIC INTRACRANIAL HEMATOMAS USING NEAR-INFRARED SPECTROSCOPY [J].
GOPINATH, SP ;
ROBERTSON, CS ;
CONTANT, CF ;
NARAYAN, RK ;
GROSSMAN, RG ;
CHANCE, B .
JOURNAL OF NEUROSURGERY, 1995, 83 (03) :438-444
[7]   Dynamic changes of cerebral oxygenation measured by brain tissue oxygen pressure and near infrared spectroscopy [J].
Holzschuh, M ;
Woertgen, C ;
Metz, C ;
Brawanski, A .
NEUROLOGICAL RESEARCH, 1997, 19 (03) :246-248
[8]   NONINVASIVE, INFRARED MONITORING OF CEREBRAL AND MYOCARDIAL OXYGEN SUFFICIENCY AND CIRCULATORY PARAMETERS [J].
JOBSIS, FF .
SCIENCE, 1977, 198 (4323) :1264-1267
[9]   AN OBSERVATIONAL STUDY OF NEAR-INFRARED SPECTROSCOPY DURING CAROTID ENDARTERECTOMY [J].
KIRKPATRICK, PJ ;
SMIELEWSKI, P ;
WHITFIELD, PC ;
CZOSNYKA, M ;
MENON, D ;
PICKARD, JD .
JOURNAL OF NEUROSURGERY, 1995, 82 (05) :756-763
[10]   Use of near-infrared spectroscopy in the adult [J].
Kirkpatrick, PJ .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES B-BIOLOGICAL SCIENCES, 1997, 352 (1354) :701-705