Magnetic resonance imaging during untreated ventricular fibrillation reveals prompt right ventricular overdistention without left ventricular volume loss

被引:38
作者
Berg, RA
Sorrell, VL
Kern, KB
Hilwig, RW
Altbach, MI
Hayes, MM
Bates, KA
Ewy, GA
机构
[1] Univ Arizona, Coll Med, Dept Pediat, Tucson, AZ 85724 USA
[2] Univ Arizona, Coll Med, Steele Mem Childrens Res Ctr, Tucson, AZ 85724 USA
[3] Univ Arizona, Coll Med, Sarver Heart Ctr, Tucson, AZ 85724 USA
[4] Univ Arizona, Coll Med, Dept Med, Tucson, AZ 85724 USA
[5] Univ Arizona, Coll Med, Dept Radiol, Tucson, AZ 85724 USA
[6] Univ Arizona, Coll Med, Dept Anesthesiol, Tucson, AZ 85724 USA
关键词
cardiopulmonary resuscitation; heart arrest; hemodynamics; magnetic resonance imaging; ventricular fibrillation;
D O I
10.1161/01.CIR.0000157147.26869.31
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Background - Most out-of-hospital ventricular fibrillation (VF) is prolonged ( > 5 minutes), and defibrillation from prolonged VF typically results in asystole or pulseless electrical activity. Recent visual epicardial observations in an open-chest, open-pericardium model of swine VF indicate that blood flows from the high-pressure arterial system to the lower-pressure venous system during untreated VF, thereby overdistending the right ventricle and apparently decreasing left ventricular size. Therefore, inadequate left ventricular stroke volume after defibrillation from prolonged VF has been postulated as a major contributor to the development of pulseless rhythms. Methods and Results - Ventricular dimensions were determined by MRI for 30 minutes of untreated VF in a closed-chest, closed-pericardium model in 6 swine. Within 1 minute of untreated VF, mean right ventricular volume increased by 29 % but did not increase thereafter. During the first 5 minutes of untreated VF, mean left ventricular volume increased by 34 %. Between 20 and 30 minutes of VF, stone heart occurred as manifested by dramatic thickening of the myocardium and concomitant substantial decreases in left ventricular volume. Conclusions - In this closed-chest swine model of VF, substantial right ventricular volume changes occurred early and did not result in smaller left ventricular volumes. The changes in ventricular volumes before the late development of stone heart do not explain why defibrillation from brief duration VF ( > 5 minutes) typically results in a pulsatile rhythm with return of spontaneous circulation, whereas defibrillation from prolonged VF ( 5 to 15 minutes) does not.
引用
收藏
页码:1136 / 1140
页数:5
相关论文
共 30 条
[1]
American Heart Association, 2000, CIRCULATION, V102, P60
[2]
Berg R, 2003, CRIT CARE MED, V31, pA33
[3]
Automated external defibrillation versus manual defibrillation for prolonged ventricular fibrillation: Lethal delays of chest compressions before and after countershocks [J].
Berg, RA ;
Hilwig, RW ;
Kern, KB ;
Sanders, AB ;
Xavier, LC ;
Ewy, GA .
ANNALS OF EMERGENCY MEDICINE, 2003, 42 (04) :458-467
[4]
Precountershock cardiopulmonary resuscitation improves ventricular fibrillation median frequency and myocardial readiness for successful defibrillation from prolonged ventricular fibrillation: A randomized, controlled swine study [J].
Berg, RA ;
Hilwig, RW ;
Kern, KB ;
Ewy, GA .
ANNALS OF EMERGENCY MEDICINE, 2002, 40 (06) :563-570
[5]
Cine MR angiography of the heart with segmented true fast imaging with steady-state precession [J].
Carr, JC ;
Simonetti, O ;
Bundy, J ;
Li, DB ;
Pereles, S ;
Finn, JP .
RADIOLOGY, 2001, 219 (03) :828-834
[6]
Time for change? [J].
Chamberlain, D ;
Handley, AJ ;
Colquhoun, M .
RESUSCITATION, 2003, 58 (03) :237-247
[7]
Influence of cardiopulmonary resuscitation prior to defibrillation in patients with out-of-hospital ventricular fibrillation [J].
Cobb, LA ;
Fahrenbruch, CE ;
Walsh, TR ;
Copass, MK ;
Olsufka, M ;
Breskin, M ;
Hallstrom, AP .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 281 (13) :1182-1188
[8]
ISCHEMIC CONTRACTURE OF HEART - STONE HEART [J].
COOLEY, DA ;
WUKASCH, DC ;
REUL, GJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1972, 29 (04) :575-&
[9]
TrueFISP: Assessment of accuracy for measurement of left ventricular mass in an animal model [J].
Fieno, DS ;
Jaffe, WC ;
Simonetti, OP ;
Judd, RM ;
Finn, JP .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (05) :526-531
[10]
Left ventricular mass:: Manual and automatic segmentation of true FISP and FLASH cine MR images in dogs and pigs [J].
François, CJ ;
Fieno, DS ;
Shors, SM ;
Finn, JP .
RADIOLOGY, 2004, 230 (02) :389-395