Determination of montelukast sodium in human plasma by column-switching high-performance liquid chromatography with fluorescence detection

被引:56
作者
Ochiai, H [1 ]
Uchiyama, N [1 ]
Takano, T [1 ]
Hara, K [1 ]
Kamei, T [1 ]
机构
[1] Banyu Pharmaceut Co Ltd, Dev Res Labs, Drug Metab, Menuma, Saitama 36002, Japan
来源
JOURNAL OF CHROMATOGRAPHY B | 1998年 / 713卷 / 02期
关键词
montelukast sodium;
D O I
10.1016/S0378-4347(98)00179-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
MK-0476 (montelukast sodium) is a potent and selective cysteinyl leukotriene receptor antagonist that is being investigated in the treatment of asthma. A simple and sensitive method for the determination of MK-0476 in human plasma was developed using column-switching high-performance liquid chromatography (HPLC) with fluorescence detection. A plasma sample was injected directly onto the HPLC system consisting of a pre-column (Capcell pak MF) and an analytical column (Capcell pak C18) which were connected with a six-port switching valve. The column eluate was monitored with a fluorescence detector (excitation at 350 nm; emission at 400 nm). The calibration curve was linear in a concentration range of 1-500 ng ml(-1) for MK-0476 in human plasma. The intra-day coefficients of variation of all concentrations within the range was less than 9.2%, and the intra-day accuracy values were between 97.2 and 114.6%. This method was used to measure the plasma concentration of MK-0476 following oral administration of the drug in humans. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:409 / 414
页数:6
相关论文
共 9 条
[1]  
ADJAYE EBA, 1994, J CHROMATOGR B, V652, P35
[2]   DETERMINATION OF MK-0476 IN HUMAN PLASMA BY LIQUID-CHROMATOGRAPHY [J].
AMIN, RD ;
CHENG, HY ;
ROGERS, JD .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1995, 13 (02) :155-158
[3]  
FALCO PC, 1993, J CHROMATOGR, V619, P177
[4]   SYNTHESIS OF POLYMER-COATED MIXED-FUNCTIONAL PACKING MATERIALS FOR DIRECT ANALYSIS OF DRUG-CONTAINING SERUM AND PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KANDA, T ;
KUTSUNA, H ;
OHTSU, Y ;
YAMAGUCHI, M .
JOURNAL OF CHROMATOGRAPHY A, 1994, 672 (1-2) :51-57
[5]   Effects of montelukast (MK-0476), a new potent cysteinyl leukotriene (LDT(4)) receptor antagonist, in patients with chronic asthma [J].
Reiss, TF ;
Altman, LC ;
Chervinsky, P ;
Bewtra, A ;
Stricker, WE ;
Noonan, GP ;
Kundu, S ;
Zhang, J .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1996, 98 (03) :528-534
[6]   SINGLE-DOSE PHARMACOKINETICS, SAFETY AND TOLERABILITY OF MK-0476, A NEW LEUKOTRIENE D-4-RECEPTOR ANTAGONIST, IN HEALTHY-VOLUNTEERS [J].
SCHOORS, DF ;
DESMET, M ;
REISS, T ;
MARGOLSKEE, D ;
CHENG, H ;
LARSON, P ;
AMIN, R ;
SOMERS, G .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1995, 40 (03) :277-280
[7]   Direct injection isocratic high-performance liquid chromatographic analysis of mitomycin C in plasma [J].
Song, D ;
Au, JLS .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 676 (01) :165-168
[8]   QUANTITATIVE-ANALYSIS OF RETINOIDS IN BIOLOGICAL-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING COLUMN SWITCHING .3. DETERMINATION OF THE AROTINOID SUMAROTENE AND ITS Z-ISOMER IN HUMAN AND ANIMAL PLASMA [J].
WYSS, R ;
BUCHELI, F .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 576 (01) :111-120
[9]   QUANTITATIVE-ANALYSIS OF RETINOIDS IN BIOLOGICAL-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING COLUMN SWITCHING .1. DETERMINATION OF ISOTRETINOIN AND TRETINOIN AND THEIR 4-OXO METABOLITES IN PLASMA [J].
WYSS, R ;
BUCHELI, F .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 424 (02) :303-314