Fully automated method for the liquid chromatographic determination of cyproterone acetate in plasma using restricted access material for sample pre-treatment

被引:27
作者
Christiaens, B [1 ]
Chiap, P [1 ]
Rbeida, O [1 ]
Cello, D [1 ]
Crommen, J [1 ]
Hubert, P [1 ]
机构
[1] Univ Liege, CHU, Inst Pharm, Dept Pharmaceut Analyt Chem, B-4000 Liege 1, Belgium
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2003年 / 795卷 / 01期
关键词
cyproterone acetate;
D O I
10.1016/S1570-0232(03)00517-8
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
A new fully automated method for the quantitative analysis of an antiandrogenic substance, cyproterone acetate (CPA), in plasma samples has been developed using on-line solid-phase extraction (SPE) prior to the determination by reversed-phase liquid chromatography (LC). The automated method was based on the use of a precolumn packed with an internal-surface reversed-phase packing material (LiChrospher RP-4 ADS) for sample clean-up coupled to LC analysis on an octadecyl stationary phase using a column-switching system. A 200-mul volume of plasma sample was injected directly on the precolumn packed with restricted access material using a mixture of water-acetonitrile (90:10, v/v) as washing liquid. The analyte was then eluted in the back-flush mode with the LC mobile phase which consisted of a mixture of phosphate buffer, pH 7.0-acetonitrile (54:46, v/v). The elution profiles of CPA and blank plasma samples on the precolumn and the time needed for analyte transfer from the precolumn to the analytical column were determined. Different compositions of washing liquid and mobile phase were tested to reduce the interference of plasma endogenous components. UV detection was achieved at 280 nm. Finally, the developed method was validated using a new approach, namely the application of the accuracy profile based on the interval confidence at 90% of the total measurement error (bias+standard deviation). The limit of quantification of cyproterone acetate in plasma was determined at 15 ng ml(-1). The validated method should be applicable to the determination of CPA in patients treated by at least 50 mg day(-1). (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:73 / 82
页数:10
相关论文
共 32 条
[1]
Application of the restricted-access precolumn packing material alkyl-diol silica in a column-switching system for the determination of ketoprofen enantiomers in horse plasma [J].
Baeyens, WRG ;
Van der Weken, G ;
Haustraete, J ;
Aboul-Enein, HY ;
Corveleyn, S ;
Remon, JP ;
García-Campaña, AM ;
Deprez, P .
JOURNAL OF CHROMATOGRAPHY A, 2000, 871 (1-2) :153-161
[2]
ISOLATION AND IDENTIFICATION OF 15-BETA-HYDROXY CYPROTERONE-ACETATE AS A NEW METABOLITE OF CYPROTERONE-ACETATE IN DOG, MONKEY AND MAN [J].
BHARGAVA, AS ;
SEEGER, A ;
GUNZEL, P .
STEROIDS, 1977, 30 (03) :407-418
[3]
DEVELOPMENT AND PERFORMANCE OF AN AUTOMATED HPLC-ANALYZER FOR CATECHOLAMINES [J].
BOOS, KS ;
WILMERS, B ;
SAUERBREY, R ;
SCHLIMME, E .
CHROMATOGRAPHIA, 1987, 24 :363-370
[4]
High-performance liquid chromatography integrated solid-phase extraction in bioanalysis using restricted access precolumn packings [J].
Boos, KS ;
Grimm, CH .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (03) :175-180
[5]
ALKYL-DIOL SILICA (ADS) - RESTRICTED ACCESS PRECOLUMN PACKINGS FOR DIRECT-INJECTION AND COUPLED-COLUMN CHROMATOGRAPHY OF BIOFLUIDS [J].
BOOS, KS ;
RUDOLPHI, A ;
VIELHAUER, S ;
WALFORT, A ;
LUBDA, D ;
EISENBEISS, F .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 352 (7-8) :684-690
[6]
BOOS KS, 1998, LC GC, V16, P84
[7]
HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ESTIMATION OF CYPROTERONE-ACETATE IN HUMAN-PLASMA [J].
CANNELL, GR ;
MORTIMER, RH ;
THOMAS, MJ .
JOURNAL OF CHROMATOGRAPHY, 1981, 226 (02) :492-497
[8]
Simultaneous determination of methylphenobarbital enantiomers and phenobarbital in human plasma by on-line coupling of an achiral precolumn to a chiral liquid chromatographic column [J].
Ceccato, A ;
Boulanger, B ;
Chiap, P ;
Hubert, P ;
Crommen, J .
JOURNAL OF CHROMATOGRAPHY A, 1998, 819 (1-2) :143-153
[9]
Ceccato A, 1999, ENANTIOMER, V4, P305
[10]
Automated determination of pirlindole enantiomers in plasma by on-line coupling of a pre-column packed with restricted access material to a chiral liquid chromatographic column [J].
Chiap, P ;
Ceccato, A ;
Gora, R ;
Hubert, P ;
Géczy, J ;
Crommen, J .