Influence of the hepatobiliary contrast agent Mangafodipir Trisodium (Mn-DPDP) on the imaging properties of abdominal organs

被引:16
作者
Jung, G [1 ]
Heindel, W [1 ]
Krahe, T [1 ]
Kugel, H [1 ]
Walter, C [1 ]
Fischbach, R [1 ]
Klaus, H [1 ]
Lackner, K [1 ]
机构
[1] Univ Cologne, Inst & Poliklin Radiol Diagnost, Sch Med, Dept Diagnost Radiol, D-50924 Cologne, Germany
关键词
MR contrast agent; manganese; liver tumors;
D O I
10.1016/S0730-725X(98)00086-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
To assess the influence of Mangafodipir Trisodium on the imaging properties of abdominal organs when using T-1-weighted gradient-echo (GE) and T-2-weighted turbo spin-echo (TSE) sequences, thirty patients with focal lesions in the liver were examined at a field strength of 1.5 T before and after intravenous administration of Mangafodipir Trisodium (dose: 5 mu mol/kg of body weight). Administration of Mangafodipir Trisodium led to a significant increase in the signal intensity of the liver tissue (p < 0.001), the spleen (p < 0.01), the pancreas (p < 0.001), and the kidneys (p < 0.001) in the T-1-weighted GE sequence, while there was no relevant enhancement in fatty tissue and the musculature. In the T-2-weighted turbo spin-echo sequence, there was no relevant change in the signal following administration of a contrast agent, The contrast-to-noise ratio (C/N) between the lesions and the liver tissue increased significantly in the post-contrast T-1-weighted GE sequence (p < 0.001), while there was no change in the contrast-to-noise ratio in the post-contrast T-2-weighted turbo spin-echo sequence, The contrast-to-noise ratio of the plain T-2-weighted TSE sequence was significantly higher than that in the postcontrast T-1-weighted GE sequence (p < 0.001). Although Mangafodipir Trisodium was primarily developed as a hepatobiliary contrast agent for demonstration and differentiation of Liver lesions, it also affects the signal levels in the pancreas, spleen, and kidneys in the T-1-weighted image. Awareness of this effect on the extrahepatic tissue makes it easier to interpret pathological findings in magnetic resonance imaging (MRI) of the abdomen. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:925 / 931
页数:7
相关论文
共 17 条
[1]
MN-DPDP - ENHANCED MR-IMAGING OF MALIGNANT LIVER-LESIONS - EFFICACY AND SAFETY IN 20 PATIENTS [J].
AICHER, KP ;
LANIADO, M ;
KOPP, AF ;
GRONEWALLER, E ;
DUDA, SH ;
CLAUSSEN, CD .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (05) :731-737
[2]
HEPATIC MR IMAGING WITH MN-DPDP - SAFETY, IMAGE QUALITY, AND SENSITIVITY [J].
BERNARDINO, ME ;
YOUNG, SW ;
LEE, JKT ;
WEINREB, JC .
RADIOLOGY, 1992, 183 (01) :53-58
[3]
PRECLINICAL EVALUATION OF MNDPDP - NEW PARAMAGNETIC HEPATOBILIARY CONTRAST AGENT FOR MR IMAGING [J].
ELIZONDO, G ;
FRETZ, CJ ;
STARK, DD ;
ROCKLAGE, SM ;
QUAY, SC ;
WORAH, D ;
TSANG, YM ;
CHEN, MCM ;
FERRUCCI, JT .
RADIOLOGY, 1991, 178 (01) :73-78
[4]
Evidence for the dissociation of the hepatobiliary MRI contrast agent Mn-DPDP [J].
Gallez, B ;
Bacic, G ;
Swartz, HM .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (01) :14-19
[5]
MN-DPDP IN MR IMAGING OF PANCREATIC ADENOCARCINOMA - INITIAL CLINICAL-EXPERIENCE [J].
GEHL, HB ;
URHAHN, R ;
BOHNDORF, K ;
KLEVER, P ;
HAUPTMANN, S ;
LODEMANN, KP ;
MATERN, S ;
SCHUMPELICK, V ;
GUNTHER, RW .
RADIOLOGY, 1993, 186 (03) :795-798
[6]
PANCREATIC ENHANCEMENT AFTER LOW-DOSE INFUSION OF MN-DPDP [J].
GEHL, HB ;
VORWERK, D ;
KLOSE, KC ;
GUNTHER, RW .
RADIOLOGY, 1991, 180 (02) :337-339
[7]
FOCAL LIVER-LESIONS - MR IMAGING WITH MN-DPDP - INITIAL CLINICAL-RESULTS IN 40 PATIENTS [J].
HAMM, B ;
VOGL, TJ ;
BRANDING, G ;
SCHNELL, B ;
TAUPITZ, M ;
WOLF, KJ ;
LISSNER, J .
RADIOLOGY, 1992, 182 (01) :167-174
[8]
Hustvedt SO, 1997, ACTA RADIOL, V38, P690
[9]
Prospective comparison of fast SE and GRASE sequences and echo planar imaging with conventional SE sequences in the detection of focal liver lesions at 1.0 T [J].
Jung, G ;
Krahe, T ;
Kugel, H ;
Gieseke, J ;
Hahn, U ;
Walter, C ;
Lackner, K .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (03) :341-347
[10]
MANGANESE DPDP AS A CONTRAST-MEDIUM FOR MRI OF FOCAL LIVER-LESIONS - PATIENT ACCEPTABILITY AND IMAGE QUALITY IN 20 PATIENTS [J].
KOPP, AF ;
LANIADO, M ;
AICHER, KP ;
GRONEWALLER, EF ;
CLAUSSEN, CD .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 157 (06) :539-547