Prescribed burns and wildfires in Colorado: Impacts of mitigation measures on indoor air particulate matter

被引:57
作者
Henderson, DE [1 ]
Milford, JB [1 ]
Miller, SL [1 ]
机构
[1] Univ Colorado, Dept Mech Engn, Boulder, CO 80309 USA
关键词
D O I
10.1080/10473289.2005.10464746
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Wildfires and prescribed burns are receiving increasing attention as sources of fine particulate matter (PM2.5). The goal of this research project was to understand the impact of mitigation strategies for residences impacted by scheduled prescribed burns and wildfires. Pairs of residences were solicited to have PM2.5 concentrations monitored inside and outside of their houses during four fires. The effect of using air cleaners on indoor PM2.5 was investigated, as well as the effect of keeping windows closed. Appropriately sized air cleaners were provided. to one of each pair of residences; occupants of all of the residences were asked to keep windows shut and minimize opening of exterior doors. Additionally, residents were asked to record all of the activities that may be a source of particulate matter, such as cooking and cleaning. Measurements were made during one prescribed burn and three wildfires during the 2002 fire season. Outdoor 24-hr average PM2.5 concentrations ranging from 6 to 38 mu g/m(3) were measured during the fires, compared with levels of 2-5 mu g/m(3) during background measurements when no fires were burning. During the fires, PM2.5 was < 3 mu g/m(3) inside all of the houses with air cleaners installed. This corresponds with a decrease of 63-88% in homes with the air cleaners operating when compared with homes without air cleaners. In the homes without the air cleaners, measured indoor concentrations were 58-100% of the concentrations measured outdoors.
引用
收藏
页码:1516 / 1526
页数:11
相关论文
共 21 条
[1]  
Brauer M., 1999, HLTH GUIDELINES VEGE, P186
[2]  
EMMANUEL SC, 2002, RESPIROLOGY, V5, P175
[3]  
*EPA, 2002, 600P99002AFBF EPA
[4]   Using time- and size-resolved particulate data to quantify indoor penetration and deposition behavior [J].
Long, CM ;
Suh, HH ;
Catalano, PJ ;
Koutrakis, P .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (10) :2089-2099
[5]   Effectiveness of in-room air filtration and dilution ventilation for tuberculosis infection control [J].
MillerLeiden, S ;
Lobascio, C ;
Nazaroff, WW ;
Macher, JM .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1996, 46 (09) :869-882
[6]   Penetration of ambient fine particles into the indoor environment [J].
Mosley, RB ;
Greenwell, DJ ;
Sparks, LE ;
Guo, Z ;
Tucker, WG ;
Fortmann, R ;
Whitfield, C .
AEROSOL SCIENCE AND TECHNOLOGY, 2001, 34 (01) :127-136
[7]   RESIDENTIAL AIR EXCHANGE-RATES IN THE UNITED-STATES - EMPIRICAL AND ESTIMATED PARAMETRIC DISTRIBUTIONS BY SEASON AND CLIMATIC REGION [J].
MURRAY, DM ;
BURMASTER, DE .
RISK ANALYSIS, 1995, 15 (04) :459-465
[8]  
Nazaroff WW, 2000, P HLTH BUILD, V2, P49
[9]  
RADKE LF, 1990, 251 FSGTR PNW US FOR
[10]   INDOOR AIR-POLLUTION, TOBACCO-SMOKE, AND PUBLIC-HEALTH [J].
REPACE, JL ;
LOWREY, AH .
SCIENCE, 1980, 208 (4443) :464-472