Serial megavoltage CT imaging during external beam radiotherapy for non-small-cell lung cancer: Observations on tumor regression during treatment

被引:149
作者
Kupelian, PA
Ramsey, C
Meeks, SL
Willoughby, TR
Forbes, A
Wagner, TH
Langen, KM
机构
[1] MD Anderson Canc Ctr, Dept Radiat Oncol, Orlando, FL 32806 USA
[2] Thompson Canc Survival Ctr, Dept Radiat Oncol, Knoxville, TN USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2005年 / 63卷 / 04期
关键词
non-small-cell lung cancer; megavoltage CT; tumor regression;
D O I
10.1016/j.ijrobp.2005.04.046
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The ability to obtain soft-tissue imaging in the treatment room, such as with megavoltage CT imaging, enables the observation of tumor regression during a course of external beam radiation therapy. In this current study, we report on the most extensive study looking at the rate of regression of non-small-cell lung cancers during a course of external beam radiotherapy by analyzing serial megavoltage CT images obtained on 10 patients. Methods and Materials: The analysis is performed on 10 patients treated with the Helical Tomotherapy Hi*Art device. All 10 patients had non-small-cell lung cancer. A total of 274 megavoltage CT sets were obtained on the 10 patients (average, 27 scans per patient; range, 9-35). All patients had at least a scan at beginning and at the end of treatment. The frequency of scanning was determined by the treating physician. The treatment was subsequently delivered with the Tomotherapy Hi*Art system. The gross tumor volumes (GTVs) were later contoured on each megavoltage CT scan, and tumor volumes were calculated. Although some patients were treated to draining nodal areas in addition to the primary tumor, only the primary GTVs were tracked. Response to treatment was quantified by the relative decrease in tumor volume over time, i.e., elapsed days from the first day of therapy. The individual GTVs ranged from 5.9 to 737.2 cc in volume at the start of treatment. In 6 of the 10 patients, dose recalculations were also performed to document potential variations in delivered doses within the tumors. The megavoltage CT scans were used, and the planned treatment was recalculated on the daily images. The hypothesis was that dose deposited in the target would increase throughout the course of radiotherapy because of tumor shrinkage and subsequent decreasing attenuation. Specifically, the dose received by 95% of the GTV (D-95) was monitored over time for each of the 6 patients treated at M. D. Anderson Cancer Center Orlando. Results: Regression of all 10 lung tumors could be observed on the serial megavoltage CT scans. The decrease in volume was observed at a relatively constant rate throughout the treatments, with no obvious initial or final plateaus. For all 10 tumors, the average decrease in volume was 1.2% per day. However, individual tumor regression rates were observed with a range of 0.6% to 2.3% per day. The lowest rate of shrinkage was observed for the smallest lesion, and the highest rate was observed in the largest lesion. Of the 6 cases in which dose recalculations were performed, 5 demonstrated a small but noticeable gradual increase in deposited doses within the tumor, with the D-95 increases ranging from 0.02% to 0.1% per day. Conclusion: With the advent of in-room soft-tissue imaging techniques such as megavoltage CT imaging with a helical tomotherapy unit, daily documentation of the status of a grossly visible targeted tumor becomes possible. The current study demonstrated that tumor regression can be documented for patients with non-small-cell lung cancer treated with helical tomotherapy. Clinical correlations between the observations made during the course of treatment and ultimate outcomes, e.g. local control, should be investigated. (c) 2005 Elsevier Inc.
引用
收藏
页码:1024 / 1028
页数:5
相关论文
共 13 条
[1]   Dosimetric evaluation of lung tumor immobilization using breath hold at deep inspiration [J].
Barnes, EIA ;
Murray, BR ;
Robinson, DM ;
Underwood, LJ ;
Hanson, J ;
Roa, WHY .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (04) :1091-1098
[2]   Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer [J].
Erridge, SC ;
Seppenwoolde, Y ;
Muller, SH ;
van Herk, M ;
De Jaeger, K ;
Belderbos, JSA ;
Boersma, LJ ;
Lebesque, JV .
RADIOTHERAPY AND ONCOLOGY, 2003, 66 (01) :75-85
[3]   Cone-beam CT with megavoltage beams and an amorphous silicon electronic portal imaging device: Potential for verification of radiotherapy of lung cancer [J].
Ford, EC ;
Chang, J ;
Mueller, K ;
Sidhu, K ;
Todor, D ;
Mageras, G ;
Yorke, E ;
Ling, CC ;
Amols, H .
MEDICAL PHYSICS, 2002, 29 (12) :2913-2924
[4]   Planning evaluation of radiotherapy for complex lung cancer cases using helical tomotherapy [J].
Kron, T ;
Grigorov, G ;
Yu, E ;
Yartsev, S ;
Chen, JZ ;
Wong, EG ;
Rodrigues, G ;
Trenka, K ;
Coad, T ;
Bauman, G ;
Van Dyk, J .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (16) :3675-3690
[5]   Prognostic factors in the treatment of node-negative nonsmall cell lung carcinoma with radiotherapy alone [J].
Kupelian, PA ;
Komaki, R ;
Allen, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (03) :607-613
[6]   Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment [J].
Mageras, GS ;
Yorke, E .
SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) :65-75
[7]   A new approach to dose escalation in non-small-cell lung cancer [J].
Mehta, M ;
Scrimger, R ;
Mackie, R ;
Paliwal, B ;
Chappell, R ;
Fowler, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (01) :23-33
[8]   Calibration of a tomotherapeutic MVCT system [J].
Ruchala, KJ ;
Olivera, GH ;
Schloesser, EA ;
Hinderer, R ;
Mackie, TR .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (04) :N27-N36
[9]   Reduction in radiation dose to lung and other normal tissues using helical tomotherapy to treat lung cancer, in comparison to conventional field arrangements [J].
Scrimger, RA ;
Tomé, WA ;
Olivera, GH ;
Reckwerdt, PJ ;
Mehta, MP ;
Fowler, JF .
AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2003, 26 (01) :70-78
[10]   Intrafractional tumor motion: Lung and liver [J].
Shirato, H ;
Seppenwoolde, Y ;
Kitamura, K ;
Onimura, R ;
Shimizu, S .
SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) :10-18