A hand immersion test under laboratory-controlled usage conditions:: the need for sensitive and controlled assessment methods

被引:19
作者
Paye, M
Gomes, G
Zerweck, CR
Piérard, GE
Grove, GL
机构
[1] Colgate Palmolive R&D, Liege, Belgium
[2] Colgate Palmolive TC, Piscataway, NJ USA
[3] KGL Skin Study Ctr, Broomal, PA USA
[4] Univ Liege, Dept Dermatopathol, B-4000 Liege, Belgium
关键词
hand immersion test; irritation; mildness; stratum corneum stripping; conductance; biometry; detergent; hand dominance;
D O I
10.1111/j.1600-0536.1999.tb06010.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 [免疫学];
摘要
Exaggerated test conditions were frequently used to investigate the cutaneous tolerance of detergent products in the past. As the sensitivity of newly designed biometric methods is steadily improving, the trend towards more realistic test conditions should be encouraged. A hand immersion test under laboratory-controlled usage conditions is presently described, fulfilling such principles. Panelists soaked their hands in 2 different hand dishwashing liquids, 2x daily for 10 min each (with successive in-solution/out-of-solution cycles) for 4 consecutive days. Products were at usual dilution for dishwashing liquids and were randomized between the dominant and non-dominant hands of panelists. Visual scoring of erythema and dryness developing on the whole hands (scoring scales including interdigital areas and joints) during the week did not allow discrimination between the 2 products. However the dominant hands were significantly more susceptible to alterations than the non-dominant hands, regardless of product attribution. In contrast, skin electrical measurements (Corneometer(R) CM800 and Skicon(R) 200) on the dorsum of the hands (muscle mass between thumb and index) and squamometry analysis of tape stripping (harvested from the same site) yielded significant differences between the 2 products. In conclusion, a hand immersion test under realistic conditions has been described, which discriminates between products when sensitive assessment methods are used to explore skin sites partially protected from daily-life skin aggressions.
引用
收藏
页码:133 / 138
页数:6
相关论文
共 22 条
[1]
Barel A O, 1997, Skin Res Technol, V3, P107, DOI 10.1111/j.1600-0846.1997.tb00171.x
[2]
Charbonnier V, 1998, Skin Res Technol, V4, P244, DOI 10.1111/j.1600-0846.1998.tb00117.x
[3]
Influence of temperature on irritation in the hand forearm immersion test [J].
Clarys, P ;
Manou, I ;
Barel, AO .
CONTACT DERMATITIS, 1997, 36 (05) :240-243
[4]
CLASSIFICATION OF SURFACTANT-CONTAINING PRODUCTS AS SKIN IRRITANTS [J].
DILLARSTONE, A ;
PAYE, M .
CONTACT DERMATITIS, 1994, 30 (05) :314-315
[5]
ANTAGONISM IN CONCENTRATED SURFACTANT SYSTEMS [J].
DILLARSTONE, A ;
PAYE, M .
CONTACT DERMATITIS, 1993, 28 (03) :198-198
[6]
SOAP CHAMBER TEST - NEW METHOD FOR ASSESSING THE IRRITANCY OF SOAPS [J].
FROSCH, PJ ;
KLIGMAN, AM .
JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1979, 1 (01) :35-41
[7]
LNAMAN BM, 1968, JOINT C COSM SCI, P21
[8]
Comparison of instrumental measurements of skin hydration [J].
Morrison, BM ;
Scala, DD .
JOURNAL OF TOXICOLOGY-CUTANEOUS AND OCULAR TOXICOLOGY, 1996, 15 (04) :305-314
[9]
MORRISON BM, 1998, AM AC DERM M ORL 27
[10]
PAYE M, 1996, P CESIO BARC SPAIN, V3, P42