Screen-printed multienzyme arrays for use in amperometric batch and flow systems

被引:13
作者
Sapelnikova, S
Dock, E
Solná, R
Skládal, P
Ruzgas, T
Emnéus, J
机构
[1] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
[2] Masaryk Univ, Dept Biochem, CS-61137 Brno, Czech Republic
关键词
flow-injection analysis; amperometric batch and flow system; screen-printed multienzyme array; enzyme electrode; tyrosinase and horseradish peroxidase-modified electrode; tyrosinase and cholinesterase-modified electrode; wastewater characterisation;
D O I
10.1007/s00216-003-2000-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Screen-printing technology for electrode fabrication enables construction of amperometric devices suitable for combination of several enzyme electrodes. To develop a biosensor array for characterisation of wastewaters, tyrosinase and horseradish peroxidase (HRP) or cholinesterase-modified electrodes were combined on the same array. The behaviour of the tyrosinase-modified electrode in the presence of hydrogen peroxide (required co-substrate for the HRP-modified electrode) and acetylthiocholine chloride (required co-substrate for cholinesterase) was studied. Performance of bi-enzyme biosensor arrays in the batch mode and in the flow-injection system are discussed.
引用
收藏
页码:1098 / 1103
页数:6
相关论文
共 40 条
[1]   Pesticide determination in tap water and juice samples using disposable amperometric biosensors made using thick-film technology [J].
Albareda-Sirvent, M ;
Merkoçi, A ;
Alegret, S .
ANALYTICA CHIMICA ACTA, 2001, 442 (01) :35-44
[2]   Multibiosensor based on enzyme inhibition analysis for determination of different toxic substances [J].
Arkhypova, VN ;
Dzyadevych, SV ;
Soldatkin, AP ;
El'skaya, AV ;
Jaffrezic-Renault, N ;
Jaffrezic, H ;
Martelet, C .
TALANTA, 2001, 55 (05) :919-927
[3]   Improved multianalyte detection of organophosphates and carbamates with disposable multielectrode biosensors using recombinant mutants of Drosophila acetylcholinesterase and artificial neural networks [J].
Bachmann, TT ;
Leca, B ;
Vilatte, F ;
Marty, JL ;
Fournier, D ;
Schmid, RD .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (3-4) :193-201
[4]   A BIOSENSOR AS WARNING DEVICE FOR THE DETECTION OF CYANIDE, CHLOROPHENOLS, ATRAZINE AND CARBAMATE PESTICIDES [J].
BESOMBES, JL ;
COSNIER, S ;
LABBE, P ;
REVERDY, G .
ANALYTICA CHIMICA ACTA, 1995, 311 (03) :255-263
[6]  
Cummings EA, 2001, J AM SOC BREW CHEM, V59, P84
[7]   Reagentless tyrosinase enzyme electrodes: Effects of enzyme loading, electrolyte pH, ionic strength, and temperature [J].
Daigle, F ;
Leech, D .
ANALYTICAL CHEMISTRY, 1997, 69 (20) :4108-4112
[8]   Amperometric flow-through biosensor for the determination of cholinesterase inhibitors [J].
Evtugyn, GA ;
Ivanov, AN ;
Gogol, EV ;
Marty, JL ;
Budnikov, HC .
ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) :13-21
[9]  
Geiss S., 1997, CHEMOMETRICS ENV ANA