Screen-printed multienzyme arrays for use in amperometric batch and flow systems

被引:13
作者
Sapelnikova, S
Dock, E
Solná, R
Skládal, P
Ruzgas, T
Emnéus, J
机构
[1] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
[2] Masaryk Univ, Dept Biochem, CS-61137 Brno, Czech Republic
关键词
flow-injection analysis; amperometric batch and flow system; screen-printed multienzyme array; enzyme electrode; tyrosinase and horseradish peroxidase-modified electrode; tyrosinase and cholinesterase-modified electrode; wastewater characterisation;
D O I
10.1007/s00216-003-2000-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Screen-printing technology for electrode fabrication enables construction of amperometric devices suitable for combination of several enzyme electrodes. To develop a biosensor array for characterisation of wastewaters, tyrosinase and horseradish peroxidase (HRP) or cholinesterase-modified electrodes were combined on the same array. The behaviour of the tyrosinase-modified electrode in the presence of hydrogen peroxide (required co-substrate for the HRP-modified electrode) and acetylthiocholine chloride (required co-substrate for cholinesterase) was studied. Performance of bi-enzyme biosensor arrays in the batch mode and in the flow-injection system are discussed.
引用
收藏
页码:1098 / 1103
页数:6
相关论文
共 40 条
[31]   THE DEVELOPMENT OF A PEROXIDASE BIOSENSOR FOR MONITORING PHENOL AND RELATED AROMATIC-COMPOUNDS [J].
RUZGAS, T ;
EMNEUS, J ;
GORTON, L ;
MARKOVARGA, G .
ANALYTICA CHIMICA ACTA, 1995, 311 (03) :245-253
[32]   Composite electrochemical biosensors:: a comparison of three different electrode matrices for the construction of amperometric tyrosinase biosensors [J].
Serra, B ;
Jiménez, S ;
Mena, ML ;
Reviejo, AJ ;
Pingarrón, JM .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (03) :217-226
[33]  
Serra B, 2001, ELECTROANAL, V13, P693, DOI 10.1002/1521-4109(200105)13:8/9<693::AID-ELAN693>3.0.CO
[34]  
2-3
[35]   Detection of carbamate pesticides in vegetable samples using cholinesterase-based biosensors [J].
Skladal, P ;
Nunes, GS ;
Yamanaka, H ;
Ribeiro, ML .
ELECTROANALYSIS, 1997, 9 (14) :1083-1087
[36]  
Skladal P, 1996, FOOD TECHNOL BIOTECH, V34, P43
[37]   Chemometrical studies on mixture analysis with a single dynamic microbial sensor [J].
Slama, M ;
Zaborosch, C ;
Wienke, D ;
Spener, F .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 44 (1-3) :286-290
[38]   Array of hope for biosensors in Europe [J].
Turner, APF .
NATURE BIOTECHNOLOGY, 1998, 16 (09) :824-824
[39]   A highly stable biosensor for phenols prepared by immobilizing polyphenol oxidase into polyaniline-polyacrylonitrile composite matrix [J].
Xue, HG ;
Shen, ZQ .
TALANTA, 2002, 57 (02) :289-295
[40]   A dual-phase biosensing system for the determination of phenols in both aqueous and organic media [J].
Zhang, S ;
Zhao, H ;
John, R .
ANALYTICA CHIMICA ACTA, 2001, 441 (01) :95-105