Electrophoresis with electrochemical detection in a polymer microdevice

被引:79
作者
Rossier, JS [1 ]
Ferrigno, R [1 ]
Girault, HH [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Inst Chim Phys, Lab Electrochim, CH-1015 Lausanne, Switzerland
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 2000年 / 492卷 / 01期
关键词
mu-TAS; capillary electrophoresis; electrochemical detection;
D O I
10.1016/S0022-0728(00)00230-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work presents the integration of an electrochemical detector in a photoablated polymer microdevice with electroosmotic driven how. The structure of the device features a separation capillary with two side arms forming the injection capillaries, an electrical decoupler and an electrochemical detector. The decoupler is composed of a microhole or microhole array perpendicular to the separation microchannel. The system allows the electrical high voltage connection between the inlet of the capillary and the decoupler; the remaining end of the separation capillary being almost free of electric field, facilitating an electrochemical detection at the end of the microchannel. Separation parameters have been varied comprising the electrophoretic potential, the time of the injection and the buffer composition. Separation of model phenolic compounds is shown here as a demonstration of the system. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:15 / 22
页数:8
相关论文
共 37 条
  • [1] BOUSSE L, 1998, HIGH PERFORMANCE DNA, P271
  • [2] Micromachining sensors for electrochemical measurement in subnanoliter volumes
    Bratten, CDT
    Cobbold, PH
    Cooper, JM
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (02) : 253 - 258
  • [3] CAPILLARY ELECTROPHORESIS WITH AMPEROMETRIC DETECTION USING A POROUS CELLULOSE-ACETATE JOINT
    CHEN, IC
    WHANG, CW
    [J]. JOURNAL OF CHROMATOGRAPHY, 1993, 644 (01): : 208 - 212
  • [4] Electrochemical analysis in picoliter microvials
    Clark, RA
    Hietpas, PB
    Ewing, AG
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (02) : 259 - 263
  • [5] Characterization of electrochemical responses in picoliter volumes
    Clark, RA
    Ewing, AG
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (06) : 1119 - 1125
  • [6] Continuous separations in microfabricated channels for monitoring ultrasmall biological environments
    Ewing, AG
    Gavin, PF
    Hietpas, PB
    Bullard, KM
    [J]. NATURE MEDICINE, 1997, 3 (01) : 97 - 99
  • [7] Characterization of electrochemical array detection for continuous channel electrophoretic separations in micrometer and submicrometer channels
    Gavin, PF
    Ewing, AG
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (18) : 3838 - 3845
  • [8] Haab BB, 1998, BIOPHYS J, V74, pA9
  • [9] CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP
    HARRISON, DJ
    MANZ, A
    FAN, ZH
    LUDI, H
    WIDMER, HM
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (17) : 1926 - 1932
  • [10] USE OF AN ON-COLUMN FRIT IN CAPILLARY ZONE ELECTROPHORESIS - SAMPLE COLLECTION
    HUANG, XH
    ZARE, RN
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (05) : 443 - 446