Cartilaginous End Plates: Quantitative MR Imaging with Very Short Echo Times-Orientation Dependence and Correlation with Biochemical Composition

被引:55
作者
Fields, Aaron J. [1 ]
Han, Misung [2 ]
Krug, Roland [1 ,2 ]
Lotz, Jeffrey C. [1 ]
机构
[1] Univ Calif San Francisco, Dept Orthopaed Surg, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
基金
美国国家卫生研究院;
关键词
INTERVERTEBRAL DISC DEGENERATION; HUMAN LUMBAR SPINE; LOW-BACK-PAIN; MAGNETIC-RESONANCE; ACHILLES-TENDON; ASSOCIATION; INNERVATION; ANISOTROPY; TRANSPORT; CELLS;
D O I
10.1148/radiol.14141082
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: To measure the T2* of the human cartilaginous end plate by using magnetic resonance (MR) imaging with very short echo times and to determine the effect of the orientation of the end plate on T2* and on relationships between T2* and biochemical composition. Materials and Methods: This study was exempt from institutional review board approval, and informed consent was not required. Thirty-four samples of three cadaveric lumbar spines (from subjects who died at ages 51, 57, and 66 years) containing cartilaginous end plates and subchondral bone were prepared. Samples were imaged with a 3-T imager for T2* quantification by using a three-dimensional very short echo time sequence (repetition time msec/echo times msec, 30/0.075, 2, 5, 12, 18). Samples were imaged with the end plate at three orientations with respect to the constant magnetic induction field: 0 degrees, 54.7 degrees, and 90 degrees. After imaging, the cartilage was assayed for its water, glycosaminoglycan, and collagen content. Pearson correlations were used to investigate the effect of orientation on the relationships between T2* and biochemical composition. Results: T2* was significantly longer when measured at an orientation of 54.7 degrees (21.8 msec +/- 2.8 [+/- standard error of the mean]) than at 0 degrees (10.0 msec +/- 0.7, P < .001) or 90 degrees (9.9 msec +/- 0.4, P < .001). At 54.7 degrees, T2* was highly correlated with glycosaminoglycan content (r = 0.85, P < .001), the collagen-to-glycosaminoglycan ratio (r = 20.79, P < .001), and water content (r = 0.62, P = .02); at 0 degrees and 90 degrees, there were no significant differences in these relationships, with a minimum P value of .19. Conclusion: T2* evaluation can allow noninvasive estimation of the degeneration of the cartilaginous end plate; however, the accuracy of T2*-based estimates of biochemical composition depends on the orientation of the end plate. (C) RSNA, 2014
引用
收藏
页码:482 / 489
页数:8
相关论文
共 29 条
[1]
Mechanical initiation of intervertebral disc degeneration [J].
Adams, MA ;
Freeman, BJC ;
Morrison, HP ;
Nelson, IW ;
Dolan, P .
SPINE, 2000, 25 (13) :1625-1636
[2]
The prevalence of MRI-defined spinal pathoanatomies and their association with Modic changes in individuals seeking care for low back pain [J].
Albert, Hanne B. ;
Briggs, Andrew M. ;
Kent, Peter ;
Byrhagen, Andreas ;
Hansen, Christian ;
Kjaergaard, Karina .
EUROPEAN SPINE JOURNAL, 2011, 20 (08) :1355-1362
[3]
The human lumbar endplate - Evidence of changes in biosynthesis and denaturation of the extracellular matrix with growth, maturation, aging, and degeneration [J].
Antoniou, J ;
Goudsouzian, NM ;
Heathfield, TF ;
Winterbottom, N ;
Steffen, T ;
Poole, AR ;
Aebi, M ;
Alini, M .
SPINE, 1996, 21 (10) :1153-1161
[4]
Morphology of the Cartilaginous Endplates in Human Intervertebral Disks with Ultrashort Echo Time MR Imaging [J].
Bae, Won C. ;
Statum, Sheronda ;
Zhang, Zhao ;
Yamaguchi, Tomonori ;
Wolfson, Tanya ;
Gamst, Anthony C. ;
Du, Jiang ;
Bydder, Graeme M. ;
Masuda, Koichi ;
Chung, Christine B. .
RADIOLOGY, 2013, 266 (02) :564-574
[5]
Sensory and sympathetic innervation of the vertebral endplate in patients with degenerative disc disease [J].
Brown, MF ;
Hukkanen, MVJ ;
McCarthy, ID ;
Redfern, DRM ;
Batten, JJ ;
Crock, HV ;
Hughes, SPF ;
Polak, JM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (01) :147-153
[6]
Effects of repetitive freeze-thawing cycles on T2 and T2*of the Achilles tendon [J].
Chang, Eric Y. ;
Bae, Won C. ;
Statum, Sheronda ;
Du, Jiang ;
Chung, Christine B. .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (02) :349-353
[7]
An interior trust region approach for nonlinear minimization subject to bounds [J].
Coleman, TF ;
Li, YY .
SIAM JOURNAL ON OPTIMIZATION, 1996, 6 (02) :418-445
[8]
Magic angle effect in magnetic resonance imaging of the Achilles tendon and enthesis [J].
Du, Jiang ;
Pak, Byung C. ;
Znamirowski, Richard ;
Statum, Sheronda ;
Takahashi, Atsushi ;
Chung, Christine B. ;
Bydder, Graeme M. .
MAGNETIC RESONANCE IMAGING, 2009, 27 (04) :557-564
[9]
THE MAGIC-ANGLE EFFECT - BACKGROUND PHYSICS AND CLINICAL RELEVANCE [J].
ERICKSON, SJ ;
PROST, RW ;
TIMINS, ME .
RADIOLOGY, 1993, 188 (01) :23-25
[10]
IMPROVED QUANTITATION AND DISCRIMINATION OF SULFATED GLYCOSAMINOGLYCANS BY USE OF DIMETHYLMETHYLENE BLUE [J].
FARNDALE, RW ;
BUTTLE, DJ ;
BARRETT, AJ .
BIOCHIMICA ET BIOPHYSICA ACTA, 1986, 883 (02) :173-177