Selection of internal standards for quantitative analysis by matrix assisted laser desorption ionization (MALDI) time-of-flight mass spectrometry

被引:47
作者
Wilkinson, WR
Gusev, AI
Proctor, A
Houalla, M
Hercules, DM
机构
[1] VANDERBILT UNIV,DEPT CHEM,NASHVILLE,TN 37235
[2] UNIV PITTSBURGH,DEPT CHEM,PITTSBURGH,PA 15260
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1997年 / 357卷 / 03期
关键词
D O I
10.1007/s002160050148
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The selection of an appropriate internal standard (IS) for quantification by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry is critical for the successful application of quantitative MALDI. Selection of the IS depends on the chemical similarity of the analyte and IS and the mass separation of the analyte and IS as a function of instrumental peak resolution. For the quantification of bovine insulin, a series of internal standards including horse heart cytochrome C, bovine insulin chain B, des-pentapeptide human insulin, and des-octapeptide porcine insulin was investigated. Des-pentapeptide human insulin was found to be the most appropriate internal standard (relative standard deviation of the standard curve slope = 2.99%, correlation coefficient = 0.988 in the range of 0.5-0.4 mu mol/L). Two methods for measuring of the MALDI signal intensity were evaluated, direct peak integration following subtraction of a linear background and non-linear least squares curve fitting. The results obtained with these methods were equivalent.
引用
收藏
页码:241 / 248
页数:8
相关论文
共 24 条
[1]   MASS RESOLUTION IMPROVEMENT BY INCORPORATION OF PULSED ION EXTRACTION IN A MATRIX-ASSISTED LASER-DESORPTION IONIZATION LINEAR TIME-OF-FLIGHT MASS-SPECTROMETER [J].
BROWN, RS ;
LENNON, JJ .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :1998-2003
[2]   ULTRAHIGH-RESOLUTION MATRIX-ASSISTED LASER-DESORPTION IONIZATION OF SMALL PROTEINS BY FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
CASTORO, JA ;
WILKINS, CL .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2621-2627
[3]   A FACILE SAMPLE PREPARATION FOR THE ANALYSIS OF SYNTHETIC ORGANIC POLYMERS BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION [J].
DANIS, PO ;
KARR, DE .
ORGANIC MASS SPECTROMETRY, 1993, 28 (08) :923-925
[4]   QUANTITATIVE-ANALYSIS OF LOW-MOLECULAR-WEIGHT COMPOUNDS OF BIOLOGICAL INTEREST BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION [J].
DUNCAN, MW ;
MATANOVIC, G ;
CERPAPOLJAK, A .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (12) :1090-1094
[5]  
ENS W, 1995, P 43 ASMS C MASS SPE, P684
[6]   QUANTITATIVE-ANALYSIS OF PEPTIDES BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETRY [J].
GUSEV, AI ;
WILKINSON, WR ;
PROCTOR, A ;
HERCULES, DM .
APPLIED SPECTROSCOPY, 1993, 47 (08) :1091-1092
[7]   IMPROVEMENT OF SIGNAL REPRODUCIBILITY AND MATRIX/COMATRIX EFFECTS IN MALDI ANALYSIS [J].
GUSEV, AI ;
WILKINSON, WR ;
PROCTOR, A ;
HERCULES, DM .
ANALYTICAL CHEMISTRY, 1995, 67 (06) :1034-1041
[8]  
Gusev AI, 1996, FRESEN J ANAL CHEM, V354, P455
[9]   QUANTITATION OF SPECIES ON CATALYST SURFACES [J].
HERCULES, DM ;
HOUALLA, M ;
PROCTOR, A ;
FIEDOR, JN .
ANALYTICA CHIMICA ACTA, 1993, 283 (01) :42-51
[10]  
HILLENKAMP F, 1991, ANAL CHEM, V63, pA1193