High-Sensitivity Flow Cytometry Provides Access to Standardized Measurement of Small-Size Microparticles-Brief Report

被引:130
作者
Robert, Stephane [1 ]
Lacroix, Romaric [1 ,2 ]
Poncelet, Philippe [3 ]
Harhouri, Karim [2 ]
Bouriche, Tarik [3 ]
Judicone, Coralie [3 ]
Wischhusen, Jennifer [3 ]
Arnaud, Laurent [2 ]
Dignat-George, Francoise [1 ,2 ]
机构
[1] Aix Marseille Univ, UMR 1076, Fac Pharm, Inst Natl Sante & Rech Med, F-13005 Marseille, France
[2] Hop La Concept, Assistance Publ Hop Marseille, Dept Haematol, Marseille, France
[3] Biocytex, Marseille, France
关键词
flow cytometry; Megamix beads; microparticles; small size vesicles; standardization; ENDOTHELIAL-DERIVED MICROPARTICLES; DYNAMIC LIGHT-SCATTERING; INFLAMMATION; BLOOD; MICROVESICLES; CALIBRATION; BEADS;
D O I
10.1161/ATVBAHA.111.244616
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-Cellular microparticles (MP) are promising biomarkers in many pathological situations. Although flow cytometry (FCM) is widely used for their measurement, it has raised controversies because the smallest MP size falls below the detection limit of standard FCM (sd-FCM). Following recent technological improvements leading to high sensitivity FCM (hs-FCM), our objectives were (1) to evaluate the potential of hs-FCM for extended MP detection, (2) to set up a standardized protocol for MP enumeration, and (3) to compare MP counts obtained with both sensitivity levels. Methods and Results-Compared with sd-FCM, hs-FCM displayed improved forward scatter resolution and lower background noise, allowing us to discriminate previously undetectable small MP in plasma samples. Using fluorescent beads with appropriate sizes (0.1/0.3/0.5/0.9 mu m) and relative amounts, a new standardized hs-FCM MP protocol was set up and provided reproducible MP counts. Applied to coronary patient samples, it resulted into 8- to 20-fold increases in MP counts as compared with sd-FCM. Interestingly, the ratio between small and large MP varied according to clinical status but also depending on MP subset, suggesting access to new biological information. Conclusion-Recent improvements in FCM provide access to previously undetectable MP and represent a new opportunity to enhance their impact as biomarkers in clinical practice. (Arterioscler Thromb Vasc Biol. 2012;32:1054-1058.)
引用
收藏
页码:1054 / U481
页数:19
相关论文
共 26 条
[1]   The role of microparticles in inflammation and thrombosis [J].
Ardoin, S. P. ;
Shanahan, J. C. ;
Pisetsky, D. S. .
SCANDINAVIAN JOURNAL OF IMMUNOLOGY, 2007, 66 (2-3) :159-165
[2]   Circulating microparticles - A potential prognostic marker for atherosclerotic vascular disease [J].
Boulanger, Chantal M. ;
Amabile, Nicolas ;
Tedgui, Alain .
HYPERTENSION, 2006, 48 (02) :180-186
[3]   Membrane microvesicles: Macromessengers in cancer disease and progression [J].
Castellana, Donatello ;
Toti, Florence ;
Freyssinet, Jean-Marie .
THROMBOSIS RESEARCH, 2010, 125 :S84-S88
[4]   A new microparticle size calibration standard for use in measuring smaller microparticles using a new flow cytometer [J].
Chandler, W. L. ;
Yeung, W. ;
Tait, J. F. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 (06) :1216-1224
[5]   Microparticles and thrombotic disease [J].
Davizon, Pavel ;
Lopez, Jose A. .
CURRENT OPINION IN HEMATOLOGY, 2009, 16 (05) :334-341
[6]   Cellular microparticles: new players in the field of vascular disease? [J].
Diamant, M ;
Tushuizen, ME ;
Sturk, A ;
Nieuwland, R .
EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2004, 34 (06) :392-401
[7]  
Dignat-George F, 2005, QUESTIONNAIRE MICROP
[8]   Sizing and phenotyping of cellular vesicles using Nanoparticle Tracking Analysis [J].
Dragovic, Rebecca A. ;
Gardiner, Christopher ;
Brooks, Alexandra S. ;
Tannetta, Dionne S. ;
Ferguson, David J. P. ;
Hole, Patrick ;
Carr, Bob ;
Redman, Christopher W. G. ;
Harris, Adrian L. ;
Dobson, Peter J. ;
Harrison, Paul ;
Sargent, Ian L. .
NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE, 2011, 7 (06) :780-788
[9]   Formation of procoagulant microparticles and properties [J].
Freyssinet, Jean-Marie ;
Toti, Florence .
THROMBOSIS RESEARCH, 2010, 125 :S46-S48
[10]   Detection and isolation of cell-derived microparticles are compromised by protein complexes resulting from shared biophysical parameters [J].
Gyoergy, Bence ;
Modos, Karoly ;
Pallinger, Eva ;
Paloczi, Krisztina ;
Pasztoi, Maria ;
Misjak, Petra ;
Deli, Maria A. ;
Sipos, Aron ;
Szalai, Aniko ;
Voszka, Istvan ;
Polgar, Anna ;
Toth, Kalman ;
Csete, Maria ;
Nagy, Gyoergy ;
Gay, Steffen ;
Falus, Andras ;
Kittel, Agnes ;
Buzas, Edit I. .
BLOOD, 2011, 117 (04) :E39-E48