Photothermal temperature control of a chemical reaction on a microchip using an infrared diode laser

被引:103
作者
Slyadnev, MN
Tanaka, Y
Tokeshi, M
Kitamori, T
机构
[1] Kanagawa Acad Sci & Technol, Integrated Chem Project, Kawasaki, Kanagawa 2130012, Japan
[2] Univ Tokyo, Sch Engn, Dept Appl Chem, Bunkyo Ku, Tokyo 1138656, Japan
关键词
D O I
10.1021/ac010318p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have demonstrated that a miniaturized device with IR laser heating of the solvents based on a photothermal effect, is capable of fast and localized control of an enzymatic reaction on a microchip under flow conditions. Using noncontact spectroscopic temperature-sensing techniques, we measured temperature dynamics and spatial distribution and compared the measurements with results of numerical simulation analysis. The device was operated at ultrafast heating and cooling rates of 67 and 53 degreesC/s, respectively, which is 30 times faster than conventional systems and 3-6 times faster than electrothermal miniaturized thermocyclers. The IR laser-mediated heater is characterized by a significantly reduced heated volume of only 5 nL, compared to existing chip-based systems with electrothermal heating. Direct heating of a sample with extremely small heat capacity led us to a fast heating rate, and efficient heat removal through heat transfer to the glass substrate resulted in a fast cooling rate. Reproducible temperature levels with dwell times shorter than 0.5 s were achieved. The enzyme reaction on a chip was successfully controlled with 0.6-s time resolution, using periodic photothermal heating by IR laser. The IR diode laser is compact and thus suits well the miniaturized system design. Our work gives the basis for integration in a chip format of a variety of chemical processes that require fast temperature control.
引用
收藏
页码:4037 / 4044
页数:8
相关论文
共 35 条
[1]  
Akahori K, 2000, MESA MG, P493
[2]  
BIALKOWSKI S, 1999, PHOTOTHERMAL SPECTRO
[3]   Microfluidic devises connected to fused-silica capillaries with minimal dead volume [J].
Bings, NH ;
Wang, C ;
Skinner, CD ;
Colyer, CL ;
Thibault, P ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3292-3296
[4]   Dual emission laser induced fluorescence for direct planar scalar behavior measurements [J].
Coppeta, J ;
Rogers, C .
EXPERIMENTS IN FLUIDS, 1998, 25 (01) :1-15
[5]   Micromachined heated chemical reactor for pre-column derivatisation [J].
Eijkel, JCT ;
Prak, A ;
Cowen, S ;
Craston, DH ;
Manz, A .
JOURNAL OF CHROMATOGRAPHY A, 1998, 815 (02) :265-271
[6]   Towards integrated continuous-flow chemical reactors [J].
Erbacher, C ;
Bessoth, FG ;
Busch, M ;
Verpoorte, E ;
Manz, A .
MIKROCHIMICA ACTA, 1999, 131 (1-2) :19-24
[7]   Characterisation of a micro-total analytical system for the determination of nitrite with spectrophotometric detection [J].
Greenway, GM ;
Haswell, SJ ;
Petsul, PH .
ANALYTICA CHIMICA ACTA, 1999, 387 (01) :1-10
[8]   The use of a novel microreactor for high throughput continuous flow organic synthesis [J].
Greenway, GM ;
Haswell, SJ ;
Morgan, DO ;
Skelton, V ;
Styring, P .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 63 (03) :153-158
[9]   MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP [J].
HARRISON, DJ ;
FLURI, K ;
SEILER, K ;
FAN, ZH ;
EFFENHAUSER, CS ;
MANZ, A .
SCIENCE, 1993, 261 (5123) :895-897
[10]  
Harrison DJ, 1996, SENSOR ACTUAT B-CHEM, V33, P105, DOI 10.1016/0925-4005(96)01932-6